LAN/RS-232 Command Reference

The V-160HD support two types of remote-interface communication: LAN and RS-232.
Using the LAN CONTROL port or RS-232 connector to send specific commands to the V-160HD from a controlling device lets you operate the
V-160HD remotely.

LAN Interface

This uses the LAN CONTROL port on the V-160HD.
You use Telnet to operate the V-160HD remotely over a LAN (TCP/IP
protocol).
Communication standards
Port
LAN CONTROL port
TCP port number
8023
Specifying the V-160HD's Network Settings
Ó
1 .
[MENU] button
"LAN CONTROL"
item shown below, and press the [VALUE] knob .
Menu item
Explanation
Selects how settings are made for the IP
address, subnet mask, and default gateway.
USING DHCP:
The IP address and other information needed
CONFIGURE
for connecting to the network is obtained
automatically from the DHCP server of the LAN.
MANUAL:
The IP address, subnet mask, and default
gateway are specified manually.
Shows the IP address. (*1)
IP ADDRESS
Shows the subnet mask. (*1)
SUBNET MASK
Shows the default gateway. (*1)
DEFAULT GATEWAY
(*1) When "CONFIGURE" is set to "MANUAL, " set these respectively
according to the network.
2 .
Use the [VALUE] knob to change the value of the setting .
3 .
Use the [VALUE] knob to select "NETWORK PASSWORD,"
and press the [VALUE] knob .
The NETWORK PASSWORD screen appears.
4 .
Set a network password (four characters) .
Input the password that's set here when connecting a computer or
other device on the same network to access the V-160HD.
5 .
Press the [MENU] button to close the menu .
20
Ó
select the menu

RS-232 Interface

RS-232 connector pin layout
1
2
3
4
5
6
7
8
9
DB-9 type (male)
Communication standards
Communication method Synchronous (asynchronous), full-duplex
Communication speed
9,600/38,400/115,200 bps
Parity
none
Data length
8 bits
Stop bit
1 bit
Code set
ASCII
Cable wiring diagram
Use an RS-232 crossover cable to connect the V-160HD and the
controller (an RS-232-compatible computer or other device).
V-160HD
N.C.: 1
RXD: 2
TXD: 3
DTR: 4
GND: 5
DSR: 6
RTS: 7
CTS: 8
N.C.: 9
(Crossover connection)
* The connections between 4 and 6 and between 7 and 8 are inside the
V-160HD.

Command Format

Commands are formatted using the configuration shown below.
Commands are all in ASCII code.
* Commands are common to the LAN and the RS-232 interface.
stx
Command code
:
ASCII code "02H" is a control code indicating the start of
stx
a command. "H" indicates that it is a hexadecimal value.
Command
This specifies the command type (three single-byte
code
alphanumeric characters).
This is appended to a command that requires one or
more parameter. The command and the parameter
Parameter
portion are separated by a " : " (colon). When there are
multiple parameters, they are each separated by " , "
(comma) characters.
This is the code that this unit recognizes as the end of
;
a command.
* The codes of stx (02H), ack (06H), xon (11H), and xoff (13H) are the
control codes.
Pin assignments
Pin No .
Signal
1
N.C.
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
N.C.
Control device
1:
2: RXD
3: TXD
4:
5: GND
6:
7:
8:
9: