SINAMICS S120
Engineering Information
S120 ALM output
Input current
at
400 V or 690 V
400 V or 690 V
Frame size Output
380 V – 480 V 3AC
FX
132 kW
FX
160 kW
GX
235 kW
GX / GXL
300 kW
HX / HXL
380 kW
HX
450 kW
HX / HXL
500 kW
JX / JXL
630 kW
JX
800 kW
JX / JXL
900 kW
500 V – 690 V 3AC
HX / HXL
630 kW
JX / HXL
800 kW
HXL
900 kW
JX / JXL
1100 kW
JX / JXL
1400 kW
JXL
1700 kW
S120 Active Infeed: Line currents at the beginning of precharging (initial rms values)
SINAMICS Engineering Manual – November 2015
362/528
Ó Siemens AG
Precharging
at
resistor R
p
per line phase
(in AIM)
210 A
6.8 Ω
260 A
6.8 Ω
380 A
3.4 Ω
490 A
3.4 Ω
605 A
2.2 Ω
745 A
2.2 Ω
840 A
2.2 Ω
985 A
1.1 Ω
1260 A
1.1 Ω
1405 A
1.1 Ω
575 A
4.0 Ω
735 A
2.0 Ω
810 A
2.0 Ω
1025 A
2.0 Ω
1270 A
2.0 Ω
1560 A
1.33 Ω
Line current at the beginning of
DC link precharging
(initial rms value)
at
400 V or 690 V
29 A
29 A
59 A
59 A
91 A
91 A
91 A
182 A
182 A
182 A
86 A
172 A
172 A
172 A
172 A
259 A
Recommended fuses
(provided externally)
to protect precharging
arm on S120 Chassis
Not required
Not required
Not required
Not required
3NE1 817-0 (50 A)
3NE1 817-0 (50 A)
3NE1 817-0 (50 A)
3NE1 021-0 (100 A)
3NE1 021-0 (100 A)
3NE1 021-0 (100 A)
3NE1 817-0 (50 A)
3NE1 021-0 (100 A)
3NE1 021-0 (100 A)
3NE1 021-0 (100 A)
3NE1 021-0 (100 A)
3NE1 021-0 (100 A)

Hide quick links: