Connection Diagram Of The Power Module - Siemens SINAMICS G130 Engineering Manual

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

4.3 Connection diagram of the Power Module

An overview of the power and signal interfaces of the SINAMICS G130 Power Module is shown below.
Power connections
·
Mains connection: U1, V1, W1, PE1
·
Motor connection: U2, V2, W2, PE2
·
DC link connection for optional braking unit: DCPA, DCNA
·
DC link connection for optional dv/dt filter plus VPL or dv/dt filter compact plus VPL: DCPS, DCNS
Signal connections and 24 V auxiliary supply
·
See connection diagram
Power Module
PE1
U1
V1
W1
P24 M
1
2
3
4
5
6
[1]
[2]
[3]
Connection diagram for power and signal connections on the SINAMICS G130 Power Module
DCPS
DCNS
DCPA
DCNA
DRIVE-CLiQ socket 0
Control Interface Module CIM
DRIVE-CLiQ socket 1
DRIVE-CLiQ socket 2
[4]
[5]
[6]
Engineering Information
[1]
Connection for an external
24 V supply
[2]
Reserved
[3]
Connection for controlling
PE2
a main contactor
[4]
Connection for a temperature sensor
U2
KTY84-130, PT1000, PT100 or PTC
for motor monitoring
V2
[5]
Connection for Safety Functions
W2
Safe Torque Off / Safe Stop 1
[6]
24 V outgoing feeder to supply
the CU320-2 Control Unit and,
if installed, AOP30, TM31 and
SMC30
[7]
Connection for Safe Brake Adapter
- X100
- X400
DRIVE-CLiQ socket
Control Unit
CU320-2
Serial interface
RS232
- X401
- X500
DRIVE-CLiQ sockets
1st Terminal
Module TM31
- X402
- X500
DRIVE-CLiQ socket
Sensor Module
SMC30
[7]
SINAMICS Engineering Manual – November 2015
SINAMICS G130
Operator Panel
AOP30
- X140 - X540
Serial interface
RS232
- X501
- X500
DRIVE-CLiQ socket
2nd Terminal
Module TM31
285/528
Ó Siemens AG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150

Table of Contents