Tech Mode
Flash Time
Default = 600 milliseconds
Set the flash time to 80, 280, or 600 milliseconds.
Pause Time
Default = 3 seconds
It sets the length of the pause time from 1 through 9
seconds, when the pause button is pressed.
Redial Interval
Default = 3 minutes
If the remote machine is busy when the machine
sends a fax using automatic dialing, the machine
automatically redials the number. Select the time
interval between automatic redial attempts. Enter
the desired redial interval using the number
keypad: 1 - 15 minutes.
Redial Count
Default = 2
Select the number of automatic redial attempts.
Enter the desired number using the number keypad:
0 - 5.
DP Make/Break
Default = 40 - 60
Select the dial pulse make and break time: 40-60 or
33-67.
3-2
Silence Time
Default = Unlimited
In ANS/FAX mode, after a call is picked up by the
answering machine, the machine monitors the line.
If a period of silence is detected on the line at any
time, the call will be treated as a fax message and
the machine begins receiving. Silence detection time
is selectable between limited (about 12 seconds) and
unlimited time.
When '12 sec' is selected, the machine switches to
receiving mode as soon as it detects a period of
silence.
When 'Unlimited' is selected, the machine waits
until the answering operation is concluded even
though a period of silence is detected. After the
answering operation is concluded, the machine
switches to receiving mode.
Error Rate
When the error rate is about to be over the setting
value, the Baud rate automatically lowers up to 2400
bps to make the error rate remain below the setting
value.
You can select the rate between 5% and 10%.