Mitsubishi Electric MELSEC-Q Series User Manual page 27

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Item
Communication method
Synchronization method
Encoding method
Network topology
Transmission format
Error control system
Connection cable
Maximum overall cable distance
(maximum transmission distance)
RAS function
Number of occupied I/O points
Internal current consumption (5VDC)
Weight
*1
In CC-Link Ver.1, increasing the number of occupied stations can increase the number of link points per station.
In CC-Link Ver.2, increasing the number of occupied stations and setting the greater value in the expanded cyclic setting
can increase the number of link points per station.
For the points, refer to the following table.
Item
Remote I/O
(RX, RY)
Remote
1 station
register
occupied
(RWw)
Remote
Number of
register
link points
(RWr)
by the
number of
Remote I/O
occupied
(RX, RY)
stations
2
Remote
stations
register
occupied
(RWw)
Remote
register
(RWr)
Broadcast polling method
Frame synchronization method
NRZI method
Bus (RS-485)
HDLC compliant
16
12
5
CRC (X
+ X
+ X
+ 1)
• Ver.1.10-compatible CC-Link dedicated cable
• CC-Link dedicated cable (Ver.1.00-compatible)
• CC-Link dedicated high-performance cable (Ver.1.00-compatible)
The cables above cannot be used at the same time. If used, normal data transmission is not
guaranteed. In addition, select a terminating resistor to be connected according to the cable
type. (
Page 76, Section 6.2.1 (3))
Depends on the transmission speed and CC-Link version. (
Page 30, Section 3.2.3)
• Standby master function
• Automatic return function
• Slave station cutoff function
• Error detection using link special relays (SBs) and link special registers (SWs)
32 points (I/O assignment: intelli 32 points)
0.46A
0.12kg
CC-Link Ver.1
Single
32 points
32 points
(30 points for a
(30 points for a
local station)
local station)
4 points
4 points
4 points
4 points
64 points
64 points
(62 points for a
(62 points for a
local station)
local station)
8 points
8 points
8 points
8 points
CHAPTER 3 SPECIFICATIONS
Specifications
Page 29, Section 3.2.2,
CC-Link Ver.2
Expanded Cyclic Setting
Double
Quadruple
32 points
64 points
(30 points for a
(62 points for a
local station)
local station)
8 points
16 points
8 points
16 points
96 points
192 points
(94 points for a
(190 points for a
local station)
local station)
16 points
32 points
16 points
32 points
3
Octuple
128 points
(126 points for a
local station)
32 points
32 points
384 points
(382 points for a
local station)
64 points
64 points
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents