Term
Universal model QCPU
High-speed Universal model QCPU
Remote I/O net mode
Remote I/O station
Remote device station
Remote net Ver.1 mode
Remote net Ver.2 mode
Remote net mode
Remote net additional mode
Remote station
Link scan (link scan time)
Local station
Disconnection
Slave station
Dedicated instruction
Standby master station
Redundant CPU
Return
14
A generic term for the following CPU modules: Q00UJCPU, Q00UCPU, Q01UCPU, Q02UCPU, Q03UDCPU,
Q03UDVCPU, Q03UDECPU, Q04UDHCPU, Q04UDVCPU, Q04UDEHCPU, Q06UDHCPU, Q06UDVCPU,
Q06UDEHCPU, Q10UDHCPU, Q10UDEHCPU, Q13UDHCPU, Q13UDVCPU, Q13UDEHCPU, Q20UDHCPU,
Q20UDEHCPU, Q26UDHCPU, Q26UDVCPU, Q26UDEHCPU, Q50UDEHCPU, and Q100UDEHCPU
A generic term for the Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, and Q26UDVCPU
A mode used to perform high-speed communications in a system consisting of a master station and remote I/O
station(s) only
A station, such as the AJ65BTB1-16D and AJ65SBTB1-16D, that exchanges I/O signals (bit data) with another station
by cyclic transmission. This station cannot perform transient transmission.
A station, such as the AJ65BT-64AD, AJ65BT-64DAV, and AJ65BT-64DAI, that exchanges I/O signals (bit data) and I/O
data (word data) with another station by cyclic transmission. This station cannot perform transient transmission.
A mode used to configure a CC-Link system consisting of a master station and Ver.1-compatible slave station(s) only
A mode used to configure a CC-Link system containing a Ver.2-compatible slave station.
Compared to the remote net Ver.1 mode, the number of cyclic points per station is increased from 128 to 896 for RX/RY,
and from 16 to 128 for RWr/RWw.
A mode used to communicate data with all stations (remote I/O station, remote device station, local station, intelligent
device station, and standby master station) in a CC-Link system.
There are three modes: remote net Ver.1 mode, remote net Ver.2 mode, and remote net additional mode.
A mode used to increase the number of cyclic points by adding a Ver.2-compatible slave station to an existing system
consisting of Ver.1-compatible slave stations only. Programs in the remote net Ver.1 mode can be used without change
because RX/RY/RWr/RWw data of a Ver.1-compatible slave station are stored in the Ver.1-compatible buffer memory
areas.
A generic term for a remote I/O station and a remote device station
Time required for all stations in a system to transmit data.
The link scan time depends on data volume and the number of transient transmission requests.
A station that performs cyclic transmission and transient transmission with the master station and other local stations.
The station is controlled by programs in the CPU module or other equivalent modules on the station.
Processing that stops data link if a data link error occurs
A generic term for a remote I/O station, remote device station, local station, intelligent device station, and standby
master station
An instruction that simplifies programming for using functions of intelligent function modules
A station that serves as a master station to continue communications if the master station fails
A generic term for the Q12PRHCPU and Q25PRHCPU
Processing that restarts data link when a station recovers from an error
Description