Description
Use display transceiver diagnosis to display the measured values of the digital diagnosis parameters for
transceiver modules.
Examples
# Display the measured values of the digital diagnosis parameters for the transceiver module in interface
GigabitEthernet 3/1/1.
<Sysname> display transceiver diagnosis interface gigabitethernet 3/1/1
GigabitEthernet3/1/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C)
36
Table 29 Command output
Field
transceiver diagnostic information
Current diagnostic parameters
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBM)
TX power(dBM)

display transceiver manuinfo

Syntax
display transceiver manuinfo { controller [ controller-type controller-number ] | interface [ interface-type
interface-number ] } [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
2: System level
Parameters
controller [ controller-type controller-number ]: Displays the electronic label data for the transceiver
module in a controller interface. The controller-type controller-number argument specifies a controller
interface by its type and number. If no controller interface is specified, this command displays the
electronic label data for the transceiver modules in all controller interfaces.
interface [ interface-type interface-number ]: Displays the electronic label data for the transceiver module
in an interface. The interface-type interface-number argument specifies represents interface type and
Voltage(V)
Bias(mA)
3.31
6.13
RX power(dBM)
TX power(dBM)
-35.64
-5.19
Description
Digital diagnosis information of the transceiver in the interface.
Current diagnostic parameters.
Digital diagnosis parameter-temperature in °C, with the precision to
1°C.
Digital diagnosis parameter-voltage in V, with the precision to 0.01
V.
Digital diagnosis parameter-bias current in mA, with the precision
to 0.01 mA.
Digital diagnosis parameter-RX power in dBM, with the precision to
0.01 dBM.
Digital diagnosis parameter-TX power in dBM, with the precision to
0.01 dBM.