Use databits to set data bits for each character.
Use undo databits to restore the default.
By default, 8 data bits are set for each character.
NOTE:
The command is only applicable to asynchronous serial interfaces, including AUX and console ports.
The router does not support data bits 5 and 6.
If the data bits on the user interface is set to 7, only English letters are supported.
The data bits settings must be identical for the user interfaces of the connecting ports on the redirection
router and the terminal device for communication.
Examples
# Use 8 data bits for each character.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] databits 8

display user-interface

Syntax
display user-interface [ num1 | { aux | console | vty } num2 ] [ summary ] [ | { begin | exclude |
include } regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
num1: Absolute number of a user interface.
aux: AUX user interface.
console: Console user interface.
vty: VTY user interface.
num2: Relative number of a user interface. For information about valid values, see Fundamentals
Configuration Guide.
summary: Displays summary about user interfaces.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.