Endress+Hauser Proline Promag 50H Technical Information

Electromagnetic flowmeter
Hide thumbs Also See for Proline Promag 50H:
Table of Contents

Advertisement

TI00048D/06/EN/14.16
71318126
The flowmeter for smallest flow rates with a modular electronic concept and/
or with flexible system integration
Application
• The measuring principle is virtually independent of pressure,
density, temperature and viscosity
• For the smallest flow quantities and demanding hygienic
applications
Device properties
• Liner made of PFA
• Sensor housing made of stainless steel (3-A, EHEDG)
• Wetted materials CIP, SIP cleanable
• Device in compact or remote version
Promag 53
• 4-line backlit display with touch control
• HART, PROFIBUS PA/DP, Modbus RS485, FF, EtherNet/IP
Products

Technical Information

Proline Promag 50H, 53H
Electromagnetic flowmeter
Solutions
Your benefits
• Flexible installation concept – numerous hygienic process
connections
• Energy-saving flow measurement – no pressure loss due to
cross-section constriction
• Maintenance-free – no moving parts
Promag 53
• Quality – software for filling & dosing, density, electrode
cleaning and also advanced diagnostics
• Easy calculation – bidirectional totalizers
• Automatic recovery of data for servicing
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline Promag 50H

  • Page 1: Technical Information

    Products Solutions Services TI00048D/06/EN/14.16 71318126 Technical Information Proline Promag 50H, 53H Electromagnetic flowmeter The flowmeter for smallest flow rates with a modular electronic concept and/ or with flexible system integration Application Your benefits • The measuring principle is virtually independent of pressure, •...
  • Page 2: Table Of Contents

    Proline Promag 50H, 53H Table of contents Function and system design ..... .3 Pressure loss ......... 28 Vibrations .
  • Page 3: Function And System Design

    Proline Promag 50H, 53H Function and system design Measuring principle Following Faraday' s law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, the flowing medium is the moving conductor.
  • Page 4: Input

    Proline Promag 50H, 53H Input Measured variable Flow velocity (proportional to induced voltage) Measuring ranges Measuring ranges for liquids Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy Flow characteristic values (SI units) Nominal...
  • Page 5: Input Signal

    Proline Promag 50H, 53H Input signal Status input (auxiliary input) • U = 3 to 30 V DC, R = 5 kΩ, galvanically isolated • Configurable for: totalizer(s) reset, positive zero return, error-message reset Status input (auxiliary input) with PROFIBUS DP and Modbus RS485 •...
  • Page 6 Proline Promag 50H, 53H Promag 53 Current output active/passive selectable, galvanically isolated, time constant selectable (0.01 to 100 s), full scale value selectable, temperature coefficient: typ. 0.005% o.r./°C (o.r. = of reading), resolution: 0.5 mA • active: 0/4 to 20 mA, R <...
  • Page 7: Signal On Alarm

    Proline Promag 50H, 53H FOUNDATION Fieldbus interface • FOUNDATION Fieldbus H1 • Transmission technology (Physical Layer): IEC 61158-2 (MBP), galvanically isolated • ITK version 5.01 • Current consumption: 12 mA • Error current FDE (Fault Disconnection Electronic): 0 mA • Bus connection with integrated reverse polarity protection •...
  • Page 8: Power Supply

    Proline Promag 50H, 53H Power supply Terminal assignment Terminal assignment, Promag 50 Order code for Terminal No. (inputs/outputs) "Input/Output" 20 (+) / 21 (–) 22 (+) / 23 (–) 24 (+) / 25 (–) 26 (+) / 27 (–) –...
  • Page 9: Supply Voltage

    Proline Promag 50H, 53H Supply voltage • 85 to 260 V AC, 45 to 65 Hz • 20 to 55 V AC, 45 to 65 Hz • 16 to 62 V DC PROFIBUS PA and FOUNDATION Fieldbus • Non-Ex: 9 to 32 V DC •...
  • Page 10: Electrical Connection

    Proline Promag 50H, 53H Electrical connection b d/(g) HART* PROFIBUS PA* FOUNDATION Fieldbus* PA(–)/FF(–) – 27 PA(+)/FF(+) + 26 – – 25 + 24 – – 23 + 22 – – 21 + 20 N (L-) 2 N (L-) 2...
  • Page 11: Electrical Connection, Remote Version

    • Ground rings can be ordered separately from Endress+Hauser as accessories. When placing the order, make certain that the ground rings are compatible with the material used for the electrodes.
  • Page 12 Proline Promag 50H, 53H Potential equalization via additional ground ring A0002651 Allen screw (process connection) O-ring seals Plastic washer (spacer) or ground ring Sensor Potential equalization via ground electrodes on process connection A0017293 Allen screw (process connection) Integrated ground electrodes...
  • Page 13: Cable Entries

    Proline Promag 50H, 53H Cable entries Power supply and electrode cables (inputs/outputs) • Cable entry M20 × 1.5 (8 to 12 mm / 0.31 to 0.47") • Sensor cable entry for armoured cables M20 × 1.5 (9.5 to 16 mm / 0.37 to 0.63") •...
  • Page 14: Performance Characteristics

    Proline Promag 50H, 53H Performance characteristics Reference operating • Error limits following DIN EN 29104, future ISO 20456 conditions • Water, typically +15 to +45°C (+59 to +113 °F); 0,5 to 7 bar (73 to 101 psi) • Specification as per calibration protocol •...
  • Page 15: Installation

    Proline Promag 50H, 53H Installation Mounting location Entrained air or gas bubble formation in the measuring tube can result in an increase in measuring errors. Avoid the following installation locations in the pipe: • Highest point of a pipeline. Risk of air entrainment.
  • Page 16 Proline Promag 50H, 53H Partially filled pipes Partially filled pipes with gradients necessitate a drain-type configuration. The empty pipe detection function (EPD) provides additional security in detecting empty or partially filled pipes. Note! Risk of solids accumulating. Do not install the sensor at the lowest point in the drain. It is advisable to install a cleaning valve.
  • Page 17: Orientation

    Proline Promag 50H, 53H Orientation An optimum orientation position helps avoid gas and air accumulations and deposits in the measuring tube. The measuring device also offers the additional empty pipe detection function (EPD) for the detection of partially filled measuring tubes, e.g. in the case of degassing fluids or varying process pressures.
  • Page 18: Inlet And Outlet Run

    Proline Promag 50H, 53H Inlet and outlet run If possible, install the sensor well clear of assemblies such as valves, T-pieces, elbows etc. Note the following inlet and outlet runs to comply with measuring accuracy specifications: • Inlet run: ≥ 5 × DN •...
  • Page 19: Length Of Connecting Cable

    Proline Promag 50H, 53H [mbar] 8 m/s 7 m/s 6 m/s 5 m/s 4 m/s max. 8° 3 m/s 2 m/s 1 m/s d / D A0016359 Pressure loss due to adapters Length of connecting cable When mounting the remote version, please note the following to achieve correct measuring results: •...
  • Page 20: Environment

    Proline Promag 50H, 53H Environment Ambient temperature range Transmitter • Standard: –20 to +60 °C (–4 to +140 °F) • Optional: –40 to +60 °C (–40 to +140 °F) Note! At ambient temperatures below –20 °C (–4 °F) the readability of the display may be impaired.
  • Page 21: Conductivity

    Proline Promag 50H, 53H Conductivity The minimum conductivity is: • ≥ 5 μS/cm for fluids generally • ≥ 20 μS/cm for demineralized water Note! In the remote version, the necessary minimum conductivity also depends on the cable length (→  19, Section "Length of connecting cable").
  • Page 22 Proline Promag 50H, 53H Process connection material: PVC-U [psi] [bar] PN 16 -60 -40 -20 0 20 40 60 80 100120140160180 [°C] 360 [°F] A0021231-EN Process connection: flange according to ASME B16.5 Process connection material: stainless steel, 1.4404 (316L) [psi]...
  • Page 23 Proline Promag 50H, 53H Process connection: flange according to JIS B2220 Process connection material: stainless steel, 1.4404 (316L) [psi] [bar] -40 -20 0 20 40 60 80 100120140160180 [°C] 360 [°F] A0021193-EN Process connection material: PVDF [psi] [bar] -40 -20 0 20 40 60 80 100120140160180 [°C] 360 [°F]...
  • Page 24 Proline Promag 50H, 53H Process connections with aseptic molded seal, DN 40 to 150 (1½ to 6") Process connection: welding nipple according to ODT/SMS; coupling according to SMS 1145 Process connection material: stainless steel, 1.4404 (F316L) [psi] [bar] PN 16 -60 -40 -20 0 20 40 60 80 100120140160180 [°C]...
  • Page 25 Proline Promag 50H, 53H Process connection: welding nipple according to ASME BPE Process connection material: stainless steel, 1.4404 (F316L) [psi] [bar] PN 40: DN 40 (1 ½ ) " PN 25: DN 50...100 (2 ...4" PN 16: DN 150 (6") -40 -20 0 20 40 60 80 100 180 [°C]...
  • Page 26 Proline Promag 50H, 53H Process connection: coupling according to DIN 11864-1, ISO 2853 Process connection material: stainless steel, 1.4404 (F316L) [psi] [bar] PN 16 -60 -40 -20 0 20 40 60 80 100120140160180 [°C] 360 [°F] A0021190-EN For order codes with suffixes +CA/+CB:...
  • Page 27: Medium Pressure Range (Nominal Pressure)

    Proline Promag 50H, 53H For order codes with suffixes +CA/+CB: [psi] [bar] PN 25: DN 40 (1 ½" PN 16: DN 50...100 ( 2...4" PN 10: DN 125...150 ( 5...6" -40 -20 0 20 40 60 80 100 180 [°C] 360 [°F]...
  • Page 28: Pressure Tightness

    Proline Promag 50H, 53H Process connections DN 40 to 150 (1½ to 6") with aseptic gasket seal 1.4404 (F316L) Nominal diameter [mm] [inch] 1½" 2" 3" 4" 6" Weld socket: ODT/SMS PN 16 (232 psi) Weld socket: EN 10357 (DIN 11850) PN 16 (232 psi) –...
  • Page 29: Vibrations

    Proline Promag 50H, 53H Vibrations Secure the piping and the sensor if vibration is severe. Note! If vibrations are too severe, we recommend the sensor and transmitter be mounted separately. Information on the permitted shock and vibration resistance →  20, "Shock and vibration resistance"...
  • Page 30: Mechanical Construction

    Proline Promag 50H, 53H Mechanical construction Design, dimensions Transmitter remote version, wall-mount housing (non Ex-zone and II3G/Zone 2) A0001150 Dimensions (SI units) 90.5 159.5 > 50 81.5 11.5 8 × M5 2 × ⌀ 6.5 Securing screw for wall mount: M6 (screw head max. 10.5 mm)
  • Page 31 Proline Promag 50H, 53H Transmitter remote version, connection housing (II2GD/Zone 1) Nicht-eigensichere Stromkreise durch IP40-Abdeckung geschützt Non-intrinsically safe circuits Ip40 protected Boucles de courant sans sécurité intrinsèque protégées par Ip40 A0002128 Dimensions (SI units) Ø F (M8) All dimensions in [mm] Dimensions (US units) Ø...
  • Page 32 Proline Promag 50H, 53H There is a separate mounting kit for the wall-mounted housing. It can be ordered from Endress+Hauser as an accessory. The following installation variants are possible: • Panel mounting • Pipe mounting Panel mounting +0.5 (+0.019) –0.5 (–0.019) 210 (8.27)
  • Page 33 Proline Promag 50H, 53H Compact version, aluminum field housing DN 2 to 25 (¹⁄₁₂ to 1") A0005426 Dimensions in SI units 2.25 M6 × 4 Total length depends on the process connections. All dimensions in [mm] Dimensions in US units ¹⁄₁₂"...
  • Page 34 Proline Promag 50H, 53H Compact version, stainless steel field housing DN 2 to 25 (¹⁄₁₂ to 1") A0005427 Dimensions in SI units 2.25 M6 × 4 Total length depends on the process connections. All dimensions in [mm] Dimensions in US units ¹⁄₁₂"...
  • Page 35 Proline Promag 50H, 53H Sensor, remote version DN 2 to 25 (¹⁄₁₂ to 1") A0005536 Dimensions in SI units 2.25 M6 × 4 16.0 26.0 Total length depends on the process connections. All dimensions in [mm] Dimensions in US units ¹⁄₁₂"...
  • Page 36 Proline Promag 50H, 53H Sensor, front view (without process connections) DN 2 to 25 (¹⁄₁₂ to 1") E – E – A0008190 Dimensions in SI units 41.6 50.2 All dimensions in [mm] Dimensions in US units ¹⁄₁₂" 0.35 ¹⁄₈" 0.35 2.44...
  • Page 37 Proline Promag 50H, 53H Sensor, wall mounting kit DN 2 to 25 (¹⁄₁₂ to 1") A0005537 Dimensions in mm (inch) Ø D 140 (5.51") 110 (4.33") 120 (4.72") 7 (0.28") 125 (4.92") 88 (3.46") Endress+Hauser...
  • Page 38 Proline Promag 50H, 53H Process connections with O-ring seal, DN 2 to 25 (¹⁄₁₂ to 1") Welding nipple according to Sensor DN Fits to piping H × B DIN EN ISO 1127 1.4404 (316L) 5*H**-B*********** [mm] DIN EN ISO 1127...
  • Page 39 Proline Promag 50H, 53H Flange according to JIS B2220: Sensor DN Fits to H × B flange 1.4404 (316L) 5*H**-F*********** [mm] B2220 [mm] [mm] [mm] [mm] [mm] [mm] 2 to 8 ND 15 62 × 42 ND 15 62 × 42...
  • Page 40 Proline Promag 50H, 53H Lap joint flange according to Sensor DN Fits to H × B JIS B2220: 10K flange PVDF 5*H**-J*********** [mm] B2220 [mm] [mm] [mm] [mm] [mm] [mm] 2 to 8 ND 15 62 × 42 ND 15 62 ×...
  • Page 41 Proline Promag 50H, 53H Hose adapter Sensor DN Fits to inside H × B 1.4404 (316L) diameter 5*H**-M/N/P*********** [mm] [mm] [mm] [mm] [mm] 2 to 8 10.0 62 × 42 12.6 62 × 42 16.0 62 × 42 • Fitting length = (2 × L) + 86 mm •...
  • Page 42 Proline Promag 50H, 53H Welding nipple according to Sensor DN Fits to piping H × B ODT/SMS 1.4404 (316L) 5*H**-V*********** [mm] ODT/SMS [mm] [mm] [mm] [mm] 2 to 8 12.7 × 1.65 12.7 16.1 62 × 42 19.1 × 1.65 16.0...
  • Page 43 Proline Promag 50H, 53H Coupling SC DIN 11851, Sensor Fits to piping H × B threaded adapter 1.4404 (316L) 5*H**-2*********** [mm] EN 10357 [mm] [mm] [mm] [mm] (DIN 11850) 2 to 8 Tube 12 × 1 Rd 28 × ¹⁄₈"...
  • Page 44 Proline Promag 50H, 53H Coupling SMS 1145, Sensor Fits to H × B threaded adapter piping 1145 DN 1.4404 (316L) 5*H**-5*********** [mm] [mm] [mm] [mm] [mm] [mm] 1" 22.6 Rd 40 × 1/6" 30.8 72 × 55 (1" ANSI) • Fitting length = (2 × L) + 86 mm •...
  • Page 45 Proline Promag 50H, 53H Lap joint flange with grounding Sensor DN Fits to H × B electrode according to EN 1092-1 flange (DIN 2501): PN 16 PVDF DKH**-FG** [mm] EN 1092-1 [mm] [mm] [mm] [mm] [mm] [mm] (DIN 2501) 2 to 8 DN 15 62 ×...
  • Page 46 Proline Promag 50H, 53H Process connections orderable only as accessories with aseptic gasket seal, DN 15 Tri-Clamp for L14 AM7 Sensor DN Fits to piping H × B 1.4404 (316L) DKH**-HF** [mm] [mm] [mm] [mm] [mm] Tube 25.4 × 1.65 22.1...
  • Page 47 Proline Promag 50H, 53H Compact version, aluminum field housing DN 40 to 150 (1½ to 6") A0005425 Dimensions in SI units 53.5 305.5 M8 × 4 34.8 258.5 318.5 M8 × 4 47.5 67.5 333.5 M8 × 6 60.2 272.5 346.5 M8 ×...
  • Page 48 Proline Promag 50H, 53H Compact version, stainless steel field housing DN 40 to 150 (1½ to 6") A0005428 Dimensions in SI units 53.5 261.5 M8 × 4 34.8 M8 × 4 47.5 67.5 275.5 M8 × 6 60.2 M8 × 6 72.9...
  • Page 49 Proline Promag 50H, 53H Sensor, remote version DN 40 to 150 (1½ to 6") A0005535 Dimensions in SI units 53.5 138.5 M8 × 4 34.8 M8 × 4 47.5 67.5 152.5 M8 × 6 60.2 M8 × 6 72.9 M8 × 6 97.4...
  • Page 50 Proline Promag 50H, 53H Sensor, front view (without process connections) DN 40 to 150 (1½ to 6") Z–Z A0005528 Dimensions in SI units ±0.5° ±0.5° 90° 60° Threaded holes 99.7 85.8 71.0 48.3 34.8 – 112.7 98.8 83.5 60.3 47.5 –...
  • Page 51 Proline Promag 50H, 53H Process connections with aseptic gasket seal, DN 40 to 150 (1½ to 6") Welding nipple according to Sensor Fits to piping EN 10357 (DIN 11850), 1.4404 (F316L) [mm] EN 10357 [mm] [mm] [mm] [mm] [mm] [mm]...
  • Page 52 Proline Promag 50H, 53H Welding nipple according to Sensor Fits to ASME BPE Piping 1.4404 (F316L) [mm] [inch] ASME [mm] [mm] [mm] [mm] [mm] [mm] [mm] Order codes: 5*H**-Q***********, DKH**-HN** 1½" 38.1 × 34.8 38.1 99.7 71.0 1.65 2" 50.8 ×...
  • Page 53 Proline Promag 50H, 53H Clamp according to Sensor Fits to Clamp ISO 2852, Fig. 2 piping ISO 2852 1.4404 (F316L) nominal diameter [mm] ISO 2037/ [mm] [mm] [mm] [mm] [mm] [mm] [mm] BS 4825-1 Order codes: 5*H**-W***********, DKH**-HC** Surface roughness: R ≤...
  • Page 54 Proline Promag 50H, 53H Tri-Clamp for L14 AM7 Sensor Fits to piping 1.4404 (F316L) [mm] [inch] ASME BPE [mm] [mm] [mm] [mm] [mm] [mm] Order codes: 5*H**-1***********, DKH**-HE** Surface roughness: R ≤ 0.8 μm 1½" 38.1 × 1.65 34.8 50.4 92.0...
  • Page 55 Proline Promag 50H, 53H Coupling DIN 11864-1, Sensor Fits to aseptic threaded hygienic piping connection, Form A 1.4404 (F316L) [mm] DN 11850 [mm] [mm] [mm] [mm] [mm] [mm] Order codes: 5*H**-3***********, DKH**-HH** Surface roughness: R ≤ 0.8 μm 42 × 1.5 Rd 65 ×...
  • Page 56 Proline Promag 50H, 53H Coupling SMS 1145, Sensor Fits to threaded adapter piping 1145 1.4404 (F316L) [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] Order codes: 5*H**-5***********, DKH**-HK** Surface roughness: R ≤ 0.8 μm 38.1 × 1.65 38.0 35.5 Rd 60 × 1/6" 92.0 71.0...
  • Page 57 Proline Promag 50H, 53H Coupling ISO 2853, Sens Fits to threaded adapter piping 2853 1.4404 (F316L) [mm] ISO 2037 [mm] [mm] [mm] [mm] [mm] [mm] [mm] / BS 4825-1 Surface roughness: R ≤ 0.8 μm 38.0 × 38.0 35.6 92.0 61.5...
  • Page 58: Weight

    Proline Promag 50H, 53H Weight Weight in SI units Nominal Compact version (DIN) Remote version (without cable; DIN) diameter Aluminum Stainless steel Sensor Transmitter (wall- field housing field housing mount housing) [mm] [kg] [kg] [kg] [kg] 10.3 10.8 15.7 16.2 12.7...
  • Page 59: Measuring Tube Specifications

    Proline Promag 50H, 53H Measuring tube Nominal diameter Pressure rating Internal diameter specifications EN (DIN) [mm] [inch] [bar] [mm] [inch] ¹⁄₁₂" PN 16 / PN 40 2.25 0.09 ¹⁄₈" PN 16 / PN 40 0.18 ³⁄₈" PN 16 / PN 40 0.35...
  • Page 60: Fitted Electrodes

    Proline Promag 50H, 53H Fitted electrodes Measuring electrodes and empty pipe detection electrodes • Standard with: 1.4435 (316L), Alloy C-22, Tantalum, Platinum • DN 2 to 8 (¹⁄₁₂ to 5/16"): without empty pipe detection electrode Process connections With O-ring: • Weld sockets (DIN EN ISO 1127, ODT/SMS) •...
  • Page 61: Remote Operation

    CE mark The measuring system is in conformity with the statutory requirements of the EC Directives. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media Authority (ACMA)".
  • Page 62: Other Standards And Guidelines

    Ordering information Detailed ordering information is available from the following sources: • In the Product Configurator on the Endress+Hauser website: www.endress.com → Select country → Instruments → Select device → Product page function: Configure this product • From your Endress+Hauser Sales Center: www.endress.com/worldwide Product Configurator - the tool for individual product configuration: •...
  • Page 63: Accessories

    Proline Promag 50H, 53H Accessories Various accessories, which can be ordered separately from Endress+Hauser, are available for the transmitter and the sensor. The Endress+Hauser service organization can provide detailed information on the order codes of your choice. Device-specific accessories For the transmitter...
  • Page 64: Communication-Specific Accessories

    Contact your Endress+Hauser representative for more information. FieldCare FieldCare is Endress+Hauser’s FDT-based plant asset management tool. It can configure all smart field units in your system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition.
  • Page 65: Documentation

    Registered trademark of the PROFIBUS Nutzerorganisation e.V., Karlsruhe, D FOUNDATION™ Fieldbus Registered trademark of the Fieldbus Foundation, Austin, USA ® Modbus Registered trademark of SCHNEIDER AUTOMATION, INC. ® HistoROM™, S-DAT®, T-DAT™, F-CHIP®, FieldCare , Fieldcheck®, FieldXpert™, Applicator® Registered or registration-pending trademarks of the Endress+Hauser Group Endress+Hauser...
  • Page 66 www.addresses.endress.com...

This manual is also suitable for:

Proline promag 53h