Olivetti DP-670 Service Manual page 65

Option copier
Table of Contents

Advertisement

Maintenance
item No.
Adjusting the scanner automatically
U411
Description
Uses a specified original and automatically adjusts the following items in the scanner and the DP scanning
sections.
Purpose
To perform automatic adjustment of various items in the scanner and the DP scanning sections.
Method
1. Press the start key.
2. Select the item. The screen for executing is displayed.
Display
SCANNER
DP(FACE UP)
Method: [SCANNER]
1. Enter the target values which are shown on the specified original (P/N: AVGR05131K) executing mainte-
nance item U425.
2. Set a specified original (P/N: AVGR05131K) on the platen.
3. Select the item.
Display
ALL
INPUT
C.A.
MTF
GAMMA
MATRIX
4. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [Complete] is displayed. If a problem occurs dur-
ing auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and operation stops.
Should this happen, determine the details of the problem and either repeat the procedure from the
beginning, or adjust the remaining items manually by running the corresponding maintenance items.
Method: [DP(FACE UP)]
1. Measure the leading edge, main scanning, and auxiliary scanning of the specified original (P/N:
AVGR11211F) and enter the values by executing maintenance item U425.
2. Set a specified original (P/N: AVGR11211F) in the DP. Cut the trailing edge of the original.
Y108671-9
Description
Automatic adjustment in the scanner section
Automatic adjustment in the DP scanning
section (first page)
Description
Automatic adjustment using the platen for: original size magnification/
leading edge timing/center line, input gamma, chromatic aberration filter,
MTF filter and matrix.
Automatic adjustment using the platen for: original size magnification/
leading edge timing/center line.
Automatic adjustment using the platen for: chromatic aberration filter.
Automatic adjustment using the platen for: MTF filter.
Automatic adjustment using the platen for: input gamma.
Automatic adjustment using the platen for: matrix.
F
R
Service Manual
Description
74 ± 1 mm
Figure 1-3-18
Original to be used for
adjustment (P/N)
AVGR05131K
AVGR11211F
5 mm
149 ± 1 mm
3K5-2
1-3-45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-670b

Table of Contents