Olivetti DP-670 Service Manual page 43

Option copier
Table of Contents

Advertisement

Maintenance
item No.
Adjustment: Trailing edge registration
U071
1. Press the interrupt key.
2. Place an original on the DP and press the start key to make a test copy.
3. Press the interrupt key.
4. Change the setting value using the cursor up/down keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
5. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U071
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Y108671-9
Original
U404
(P.1-3-28)
Service Manual
Description
Copy
Copy
example 1
example 2
Figure 1-3-9
3K5
1-3-23