3K5-1
Maintenance
item No.
Adjusting the DP scanning timing
U071
Description
Adjusts the DP original scanning timing.
Purpose
Make the adjustment if there is a regular error between the leading or trailing edges of the original and the
copy image when the DP is used.
Method
1. Press the start key.
2. Select the item to be adjusted.
Display
ADJUST
DATA1
ADJUST
DATA2
ADJUST
DATA3
ADJUST
DATA4
ADJUST
DATA1(H)
ADJUST
DATA2(H)
ADJUST
DATA3(H)
ADJUST
DATA4(H)
Adjustment: leading edge registration
1. Press the system menu key.
2. Place an original on the DP and press the start key to make a test copy.
3. Press the system menu key.
4. Change the setting value using the +/- or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
5. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U071
1-3-6
Description
Leading edge registration (first page)
Trailing edge registration (first page)
Leading edge registration (second
page)
Trailing edge registration (second
page)
Leading edge registration at high-
speed scanning (first page)
Trailing edge registration at high-speed
scanning (first page)
Leading edge registration at high-
speed scanning (second page)
Trailing edge registration at high-speed
scanning (second page)
Original
U404
(P.1-3-12)
Service Manual
Description
Setting
range
-32 to 32
-32 to 28
-32 to 32
-32 to 28
-32 to 32
-32 to 28
-32 to 32
-32 to 28
Copy
Copy
example 1
example 2
Figure 1-3-2
Initial
Change in
setting
value per step
0
0.196 mm
0
0.196 mm
0
0.196 mm
0
0.196 mm
0
0.196 mm
0
0.196 mm
0
0.196 mm
0
0.196 mm