Kyocera PF-740 Service Manual page 89

Table of Contents

Advertisement

Connector
Pin
YC5
1
Connected to
2
the PF paper
3
conveying
4
cover switch,
PF paper con-
5
veying sen-
6
sor 1, PF
7
paper con-
veying clutch
8
1, PF pickup
9
solenoid 1,
PF paper sen-
10
sor 1, PF lift
11
sensor 1, PF
feed sensor 1.
12
13
14
15
16
17
18
19
YC6
1
Connected to
2
the PF paper
3
gauge sensor
4
2 lower, PF
paper gauge
sensor 2
5
upper, PF
6
size detec-
7
tion switch 2,
PF cassette
8
detection
9
switch 2.
10
11
12
13
14
Signal
I/O
GND
-
R_COVER_SW
I
VFDCL
O
24V1
O
VFDSW_PW
O
GND
-
VFDSW
I
24V
O
PF_R_SOL_ACT
O
PF_R_SOL_KEP
O
EMPTY_R_SW_
O
PW
GND
-
EMPTY_R_SW
I
LIMIT_R_SW_P
O
W
GND
-
LIMIT_R_SW
I
3.3V1
O
FD_R_SW
I
GND
-
PAP_L_SW1_P
O
W
GND
-
PAP_L_SW1
I
PAP_L_SW2_P
O
W
GND
-
PAP_L_SW2
I
NC
-
GND
-
NC
-
NC
-
GND
-
NC
-
SIZE_L_SW_PW
O
GND
-
Voltage
-
Ground
0/3.3 V DC
PFPCCSW: On/Off
0/24 V DC
PFPCCL1: On/Off
24 V DC
24 V DC power output to PFPCCL1
1.2 V DC
1.2 V DC power output to PFPCS1
-
Ground
0/3.3 V DC
PFPCS1: On/Off
24 V DC
24 V DC power output to PFPUSOL1
0/24 V DC
PFPUSOL1: On/Off (actuate)
0/24 V DC
PFPUSOL1: On/Off (keep)
1.2 V DC
1.2 V DC power output to PFPS1
-
Ground
0/3.3 V DC
PFPS1: On/Off
1.2 V DC
1.2 V DC power output to PFLS1
-
Ground
0/3.3 V DC
PFLS1: On/Off
3.3 V DC
3.3 V DC power output to PFFS1
0/3.3 V DC
PFFS1: On/Off
-
Ground
1.2 V DC
1.2 V DC power output to PFPGS2(L)
-
Ground
0/3.3 V DC
PFPGS2(L): On/Off
1.2 V DC
1.2 V DC power output to PFPGS2(U)
-
Ground
0/3.3 V DC
PFPGS2(U): On/Off
-
Not used
-
Ground
-
Not used
-
Not used
-
Ground
-
Not used
1.2 V DC
1.2 V DC power output to PFSDSW1
-
Ground
2-3-3
Description
3NF

Advertisement

Table of Contents
loading