4.15.3 Heater Function Check

EXECUTION MODE
Normal Mode
PROCEDURE
1.
Turn the printer ON.
2.
Start the Service Program and select
3.
Select the heater(s) to be checked, and click [Run].
The selected heater(s) starts to heat up and reaches a predetermined temperature
after about 5 minutes.
4.
Touch the heater(s) and check that it is warm.
If the heater(s) temperature does not reach the predetermined level within 10
minutes, an error is displayed.
In a cool environment, it may take a longer time to heat up the
C A U T I O N
heaters. (If the ambient temperature is 10 degrees C, it may take 20
minutes or longer.)
5.
Click [Finish].
6.
Turn the printer OFF to finish the adjustment.
ADJUSTMENT
Heater Function
Check.
Other Printer Checks and Adjustments
Figure 4-64. [Heater Function Check] Screen
Revision B