SC-S30600 Series
4.15.3 Heater Function Check
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Turn the printer ON.
2.
Start the Service Program and select
3.
Select the heater(s) to be checked, and click [Run].
The selected heater(s) starts to heat up and reaches a predetermined temperature
after about 5 minutes.
4.
Touch the heater(s) and check that it is warm.
If the heater(s) temperature does not reach the predetermined level within 10
minutes, an error is displayed.
In a cool environment, it may take a longer time to heat up the
C A U T I O N
heaters. (If the ambient temperature is 10 degrees C, it may take 20
minutes or longer.)
5.
Click [Finish].
6.
Turn the printer OFF to finish the adjustment.
ADJUSTMENT
Heater Function
Check.
Other Printer Checks and Adjustments
Figure 4-64. [Heater Function Check] Screen
Revision B
270
Confidential