1. Have the water pump and check valve inspected and cleaned by a qualified service technician.
2. Have the CO
gas check valve inspected and cleaned by a qualified service technician.
2
D
V
ISPENSING
ALVES
Refer to addendum supplied with the unit that is applicable to the manufacturer of the valves installed on the
unit.
P
T
RODUCT
UBING
IMPORTANT:Only trained and qualified persons should perform these cleaning and sanitizing
procedures.
Sanitize Pre-Mix And Post–Mix Tank System
1. Remove all the quick disconnects from all the tanks. Fill a suitable pail or bucket with soap solution.
2. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle
brush. (Do not use a wire brush). Rinse with clean water.
3. Prepare sanitizing solution and using a mechanical spray bottle, spray the disconnects. 
Allow to air dry.
4. Using a clean, empty tank, prepare five (5) gallons of the sanitizing solution. Rinse the tank disconnects
with approximately 9 oz. of the sanitizing solution. Close the tank.
5. Prepare cleaning tank by filling clean five (5) gallon tank with a mixture of mild detergent and potable water
o
(120
F).
6. Connect a gas disconnect to the tank and then apply one of the product tubes to the cleaning tank. Oper-
ate the appropriate valve until liquid dispensed is free of any syrup.
7. Disconnect cleaning tank and hook up sanitizing tank to syrup line and CO
8. Energize beverage faucet until chlorine sanitizing solution is dispensed through the faucet. Flush at least
two (2) cups of liquid to ensure that the sanitizing solution has filled the entire length of the syrup tubing.
9. Allow sanitizer to remain in lines for fifteen (15) minutes.
10. Repeat the step above, applying a different product tube each time until all tubes are filled with the sanitiz-
ing solution.
11. Remove the nozzle and syrup diffuser and clean them in a mild soap solution.
Rinse with clean water and reassemble the nozzle and syrup diffuser on the valve.
12. Rinse the parts in clean water, reassemble the valve and reconnect it to the dispenser.
13. Discard the tank of sanitizing solution and reconnect the product syrup tanks. Operate the valves until all
sanitizer has been flushed from the system and only product syrup is flowing.
Sanitize syrup lines BIBSystems
1. Remove all the quick disconnects from all the BIBcontainers.
2. Fill a suitable pail or bucket with soap solution.
3. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle
brush. (Do not use a wire brush). Rinse with clean water.
4. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
5. Rinse the BIBdisconnects in the sanitizing solution.
6. Sanitizing fittings must be attached to each BIBdisconnect. If these fittings are not available, the fittings
from empty BIBbags can be cut from the bags and used. These fittings open the disconnect so the sanitiz-
ing solution can be drawn through the disconnect.