Sanitize Pump System

Prepare Dispenser for Use

Publication Number: 620048956SER
1. Fill a clean concentrate container with 2 quarts (1.9L) of fresh sanitizing
solution.
2. Place Dispense/Flush levers (located on the platform assembly in the
refrigerated cabinet) to the
Dispense/Flush
Levers
Mixing
Chambers
Figure 9. Dispense/Flush Levers
3. Press and hold the dispense button for 90 seconds then release. Allow
sanitizing solution to remain in the lines for 5 minutes.
4. After 5 minutes, dispense the remaining sanitizing solution.
1. Replace sanitizing solution container with a concentrate container and close
the door.
2. Press and hold the dispense button until juice appears from the nozzle. Next
dispense and discard at least two 8 oz. (236.6ML) cups of juice in order to
prime the system and prepare it for operation.
- 14 -
Dispense
position.and close the door.
Figure 10. Dispense Buttons
© 2010-2014, Cornelius Inc.