IntelliCarb Drop-In Ice Cooled Installation Guide
10. Connect carbonator motor 3 wire plug to the tower 3 wire harness. Connect the tower 2 wire harness to the
transformer
11. Connect CO
line from bundled tubing to fixed secondary regulator inlet fitting.Connect tubing from sec-
2
ondary regulator outlet to carbonator tank CO
wire harness.
12. For 2323 Drop-In install a tee in water line (must be before pump). Run one line to carbonator pump inlet.
Run other line to another tee.Connect two lines from second tee to "W1 & W2" plain water connections.
Connect carbonator pump outlet to "S"
13. Connect syrup lines.
14. Connect fittings and drain hoses to ice bin and drip tray drains. Run separate hoses all the way to the drain.
Allow a 3" air gap between the drain and the end of the hose. All connections must comply with local
plumbing and health codes.
15. Turn water supply on. Plug in water booster pump (on BIB rack). After the booster pump cycles off, check
that water pressure regulator is set at 60 psi.
Publication Number: 630460204INS
Figure 11.
inlet.Route CO
line down center channel raceway with
2
2
Figure 12.
Figure 13.
- 14 -
© 2003-2017, Cornelius Inc.