Trouble
Dispensed product comes out
of dispensing valve clear but
foams in cup or glass - (Cont'd)
NOTE: If water supply is dirty, be sure to flush lines and carbonator completely. It may be nec-
essary to remove lines to carbonator tank. Flush tank and all inlet lines to remove any foreign
particles or dirt.
No product dispensed from
one dispensing valve
Only carbonated water dis-
pensed.
Only syrup dispensed
© 2003-2017, Cornelius Inc.
Probable Cause
C. Syrup over-carbonated with CO
as indicated by bubbles in inlet
syrup lines leading to unit.
D. Warm product-No ice in bin,
bridged ice on cold plate or
plugged drain.
A. Broken or disconnected wiring.
B. Inoperative dispensing valve sole-
noid coil.
C. Inoperative dispensing valve
micro switch.
A. Quick disconnects not secure on
syrup tanks.
B. Out of syrup.
C. B-I-B connectors not properly
connected.
D. Syrup secondary CO
not properly adjusted.
E. Inoperable dispensing valve.
F. Dispensing valve syrup flow regu-
lator not properly adjusted.
G. Dispensing valve syrup flow regu-
lator, syrup tank quick disconnect,
or syrup lines restricted.
A. Plain water inlet supply line shut-
off valve closed.
B. Carbonator power cord
unplugged from electrical outlet.
- 35 -
IntelliCarb Drop-In Ice Cooled Installation Guide
C. Remove syrup tanks quick dis-
2
connects. Relieve tank CO
sure, shake tank vigorously, then
relieve tank CO
many times as necessary to
remove over-carbonation.
D. Replenish ice, break ice up to
eliminate bridging, unplug the
drain.
A. Repair or connect wiring.
B. Replace solenoid coil as
instructed.
C. Replace micro switch as
instructed.
A. Secure quick disconnects on
syrup tanks.
B. Replenish syrup supply as
instructed.
C. Properly attach the connectors.
regulator
D. Adjust syrup tanks secondary
2
CO
regulator as instructed.
2
E. Repair dispensing valve.
F. Adjust dispensing valve syrup
flow regulator (Water-to Syrup
"Ratio") as instructed.
G. Sanitize syrup system as
instructed.
A. Open plain water inlet supply line
shutoff valve.
B. Plug carbonator power cord into
electrical outlet.
Remedy