Fan Failure; Mpu Failure; Lpu And Switching Fabric Module Failure - HP FlexFabric 11908-V Installation Manual

Flexfabric 11900 series
Table of Contents

Advertisement

7.
Plug a new power supply of the same model into the same slot, and connect it to the same power
input end. If the new power supply can operate correctly, the old power supply has failed. You
must replace the old power supply.

Fan failure

Both the MPU and the fan tray provide the fan tray LEDs, including an OK LED and a FAIL LED. When the
fan tray operates correctly, the OK LED is on, and the FAIL LED is off.
If the OK LED is off or the FAIL LED is on, the fan tray has failed. To troubleshoot the fan tray:
1.
If both LEDs are off, verify that the power supplies are operating correctly. For more information,
see
"Power supply system
2.
Verify that the air intakes and exhaust vents of the chassis are not blocked. If they are blocked,
clean them to keep good ventilation.
3.
Verify that the fan tray is fully seated. You can unplug the fan tray, plug it again, and then fasten
the screws.
4.
Verify that the empty LPU slots and power supply slots are installed with blank filler panels. If not,
install blank filler panels for them to guarantee good ventilation.
5.
If the failure persists, contact HP Support for help.

MPU failure

The status LEDs on the MPU show the status of a card in the corresponding slot. According to the slot
number of an MPU, you can verify the corresponding LEDs for the MPU.
When the MPU operates correctly, the RUN LED flashes and the ALM LED is off. When the RUN LED is
off, the MPU fails. To troubleshoot the MPU:
1.
Verify that the power supply operates correctly. For more information, see
failure."
Verify that the MPU is fully seated. You can unplug the MPU, plug it again, and make sure the MPU
2.
is fully seated.
3.
Press the RESET button of the MPU to reset the MPU. After the MPU is reset, verify whether the
corresponding RUN LED is on.
4.
If the switch has an empty MPU slot, plug the MPU into the slot to test the MPU.
5.
If the failure persists, contact HP Support for help.

LPU and switching fabric module failure

Use the card status LEDs on the MPU to identify the failure of the LPU or switching fabric module in a
particular slot.
If a card is operating correctly, the RUN LED flashes and the ALM LED is off. When the RUN LED is off,
the card fails. To troubleshoot the card:
1.
Verify that the MPU is operating correctly. For more information, see
2.
Verify that the software version is compatible with the card. If not, upgrade the software to a
compatible version.
failure."
48
"Power supply system
"MPU
failure."