Error Messages - Yamaha aventage RX-A3070 Owner's Manual

Hide thumbs Also See for aventage RX-A3070:
Table of Contents

Advertisement

Error messages

If any error message is displayed during the measurement, resolve the problem and perform YPAO again.
Error message
E-1: No Front SP
Front speakers are not detected.
E-2: No Sur. SP
One of the surround speakers cannot be detected.
E-3: No F.PRNS SP
One of the front presence speakers cannot be detected.
E-4: SBR → SBL
A surround back speaker is connected to the R side only.
E-5: Noisy
The noise is too loud.
Surround back speakers are connected, but no surround speakers
E-6: Check Sur.
are connected.
E-7: No MIC
The YPAO microphone has been removed.
E-8: No Signal
The YPAO microphone cannot detect test tones.
E-9: User Cancel
The measurement has been canceled.
E-10: Internal Error
An internal error has occurred.
E-11: No R.PRNS SP
One of the rear presence speakers cannot be detected.
Cause
Follow the on-screen instructions to exit YPAO, turn off the unit, and then check the speaker connections.
When using only one surround back speaker, you need to connect it to the SINGLE jack (L side). Follow the on-screen
instructions to exit YPAO, turn off the unit, and then reconnect the speaker.
Keep the room quiet and follow the on-screen instructions to start the measurement again. If you select "PROCEED",
YPAO takes the measurement again and ignores any noise detected.
Surround speakers need to be connected in order to use surround back speakers. Follow the on-screen instructions
to exit YPAO, turn off the unit, and then reconnect the speakers.
Connect the YPAO microphone to the YPAO MIC jack firmly and follow the on-screen instructions to start the
measurement again.
Connect the YPAO microphone to the YPAO MIC jack firmly and follow the on-screen instructions to start the
measurement again. If this error occurs repeatedly, contact the nearest authorized Yamaha dealer or service center.
Follow the on-screen instructions to start the measurement again. To cancel the measurement, select "EXIT".
Follow the on-screen instructions to exit YPAO, turn off and on the unit. If this error occurs repeatedly, contact the
nearest authorized Yamaha dealer or service center.
Follow the on-screen instructions to exit YPAO, turn off the unit, and then check the speaker connections.