Preparing The Installation Site; Locating A Proper Site - Pace i3822V Installation Manual

Homeportal intelligent gateway
Table of Contents

Advertisement

The following figure shows the connection between the power supply unit and i3822V.
+
POWER
BATTERY
SILENCE ALARM

Preparing the installation site

Unlike the i3822V, the iPSU must be installed in a sheltered area, either inside the
garage or home. The iPSU with a battery installed weighs approximately 11 pounds.
Make sure that the selected wall stud is strong enough to support the weight.

Locating a proper site

You can mount the iPSU on any flat surface (wood, brick, or stone) and at any height
level, from eye to floor level. Unless it is demanded by the subscriber that the iPSU be
mounted on the floor level, mount the iPSU above the floor level and away from any
areas with a potential for standing water.
The life of the battery is affected by the local environment; select a site that is away
from excessive heat, machinery, and vibration. Locate a stud wall inside the home or
garage that is within eight feet of the nearest electrical outlet (the length of the
supplied power adapter) and strong enough to support 11 pounds (the weight of iPSU
with a battery installed).
Note: Do not use an extension cord.
The iPSU contains live electronics. Any standing water that is above four inches from
the bottom edge of the iPSU can damage the iPSU wiring, which might affect the
performance of the i3822V. The lead-acid battery is sealed and will not be damaged
by the water exposure.
24
Chapter 3
Installing the iPSU (Power Supply Unit)

Advertisement

Table of Contents
loading

This manual is also suitable for:

I38hgIpsuHomeportal i3822vHomeportal i38hgHomeportal ipsu

Table of Contents