Diagnostic Codes - PIAGGIO Vespa LX 150 4T Euro 3 Service Station Manual

Table of Contents

Advertisement

Vespa LX 125 - 150 4T Euro 3
- Alternatively insert all the available black keys
and turn each one of them to "ON" for 2 seconds.
- Insert the MASTER key again and turn it to "ON"
for 2 seconds.
The maximum time to change keys is 10 seconds.
A maximum of 7 service keys (blue) can be pro-
grammed at one time.
Sequence and times must be strictly observed or
it will be necessary to repeat the procedure from
the start.
Once the control unit has been programmed, the
control unit is inseparably matched with the MAS-
TER key transponder.
This matching allows programming further service
keys in case of loss, replacement, etc. Each new
time new data is programmed the previously stor-
ed one is deleted.
If a service key setting is lost, it is essential to
carefully check the efficiency of the high voltage
system:
Shielded cap resistance ~ 5000 Ω.
In any case, it is advisable to use resistive spark
plugs as shown in the figure.

Diagnostic codes

The flash indicating the switching to "ON" (0.7-sec
flash) can be followed by a phase of programmed
failure warnings.
That is, the LED is off for 2 seconds, and then di-
agnosis codes are transmitted with 0.5-sec flash-
es.
After the failure code indication, a steadily on LED
signals that ignition is disabled; see the table:
2-FLASH CODE
Example with programmed electronic control unit,
no transponder and/or aerial malfunction
Ignition disabled-Vehicle immobilised
Electrical system
ELE SYS - 19

Hide quick links: