Horizontal Right With Right Vent - Rheem 96P series Installation Instructions Manual

4 position condensing two-stage psc gas furnaces
Hide thumbs Also See for 96P series:
Table of Contents

Advertisement

INSTALL CONDENSATE TRAP
3
4a - REMOVE METAL BRACKET AND THE Ø.403 DRAIN
PLUG- DISCARD.
4b - REMOVE HOSE "A" - DISCARD
4c - INSTALL Ø .559" CONDENSATE DRAIN PLUG AND
CONDENSATE TRAP GASKET AS SHOWN.
4d - INSTALL CONDENSATE TRAP. MAKE SURE THE
CHANNEL AT THE LOCATION SHOWN IN THE "IMPORTANT
SECTION" ENGAGES THE EDGE OF THE JACKET AT THE
LOCATION SPECIFIED.
4e - SECURE USING (3) SCREWS.
NOTE: TO PREVENT DAMAGE TO THE TRAP, THE INSTALLER MAY ELECT TO
INSTALL IT DURING A LATER STEP. (AFTER THE UNIT IS ROTATED)
NOTE: REMAINING STEPS SHOWN WITH FURNACE IN HORIZONTAL RIGHT ORIENTATION
5
TO FIT (APPROX. 4")
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
DRILL (3)
Ø1/8" HOLES
3b
4
INSTALL CONDENSATE TRAP
4b
HOSE A
DISCARD
5a
ROTATE
UNIT 90°
INSTALL
CUT
5b
1/4" TUBE CUT
5a - ROTATE UNIT 90
5b - CUT 1/4" VENT HOSE TO FIT (APPROX. 5-1/2") AND INSTALL AS SHOWN.
5c - CUT HOSE E AT LINE 1- INSTALL
5d - CUT HOSE F ON LINE CORRESPONDING TO UNIT WIDTH AND INSTALL
3a - REMOVE RECTANGLE FLUSH MOUNT PLUG
FROM JACKET SIDE-DISCARD
3b - PRE-DRILL (3) Ø 1/8" HOLES AS SHOWN
FOR CONDENSATE TRAP
RECTANGLE PLUG
DISCARD
3a
4a
DISCARD
4c
INSTALL
4d
SEE CRITICAL HOSE CLAMP LOCATION NOTE IN
THE GENERAL CONVERSION INSTRUCTIONS.
NOTE: MAKE SURE CUT IS STRAIGHT AND SQUARE
NOTE: 17.5": LINE 1, 21": LINE 2, 24.5": DO NOT CUT
!! IMPORTANT !!
CONDENSATE TRAP
INFORMATION
JACKET
THIS CHANNEL
MUST ENGAGE
JACKET AT THIS
EDGE TO AVOID
AIR LEAKS TO
TRAP
THE BURNER
VESTIBULE!
INSTALL
INSTALL
CUT
IF REQ'D.
CUT
HOSE E
HOSE F
5c
5d
ST-A1194-32-01
29