GAS FURNACES
RGPH- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
(U.S. & Canadian Models)
ENER
UIDE
AFUE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
HIGH
78%
82%
88%
97%
CRITERION
80.0%–81.4% A.F.U.E.
UPFLOW/
HORIZONTAL
GAS FURNACES
®
The Rheem
Criterion II line of upflow/horizontal gas fur-
naces are designed for utility rooms, closets, alcoves, or
attics. Because of the Criterion's low-profile 34 inch
[864 mm] height, the upflow model can also be used to
satisfy most applications that traditionally call for a
horizontal furnace.
The design is certified by CSA International.
Features
Patented Heat Exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
Low profile "34 inch" design is lighter and easier to han-
dle, and leaves room for optional equipment.
Convertible from upflow to horizontal left or right without
field conversion.
Left or right side gas and electric inlet connections with
quick, simple change.
Direct spark ignition models utilize remote sense and fea-
ture an integrated board with humidifier and electronic air
cleaner hookups.
Insulated blower compartment helps to reduce jacket loss
and noise.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with
Rheem Criterion II gas furnaces are available as optional
accessories.
These furnaces can be installed in an upflow position or laid
on either side in a horizontal position. Field conversion not
required.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
FORM NO. G11-448 REV. 10
Supersedes Form No. G11-448 Rev. 9
II
®

Advertisement

Table of Contents
loading

Summary of Contents for Rheem rgph-10eamer

  • Page 1 Annual Fuel Utilization Efficiency - A variety of cooling coils and plenums designed to use with THIS MODEL 80.0% Rheem Criterion II gas furnaces are available as optional HIGH accessories. These furnaces can be installed in an upflow position or laid on either side in a horizontal position.
  • Page 2: Product View

    Completely assembled and wired; induced draft blower; pressure switch; All models can be converted by a qualified Rheem distributor or local service redundant main gas control; blower compartment door safety switch; solid dealer to use L.P. (propane) gas without changing burners. Factory approved state time on/time off blower control;...
  • Page 3: Specifications

    [519-628 L/s] 100,000 [29 kW] R = 11 x 10 G = 1450-1750 CFM 125,000 [37 kW] [279 x 254 mm] [684-826 L/s] 150,000 [44 kW] J = 1800-2075 CFM [850-979 L/s] [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 4: Upflow Dimensions

    May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 5: Horizontal Dimensions

    May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 6: Accessories

    Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. *Designates “E” or “N”. RXPF-F01 and F02 FOSSIL FUEL KITS are for use with Rheem Heat Pumps and Criterion II warm air furnaces. The RXPF-F02 meets TVA requirements.
  • Page 7: Blower Performance Data

    [ ] Designates Metric Conversions GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product Gas Heat Exchanger Limited Warranty ..Twenty (20) Years which fails in normal use and service within the applicable *Any Other Part..........Five (5) Years...
  • Page 8 Federal, State, Provincial, and Local codes, regulations, and practices. 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 9-02 DC FORM NO.

Table of Contents