Object Id (Oid) Number And Value Range Tables - Extron electronics AXI 22 AT User Manual

Audio expansion interfaces
Hide thumbs Also See for AXI 22 AT:
Table of Contents

Advertisement

Object ID (OID) Number and Value Range Tables

Gain values should be entered as an unsigned integer. Attenuation values should be entered
as negative integers.
NOTES:
Input
OID
Mic/Line Input 1
40000
Mic/Line Input 2
40001
Mic/Line Input 3
40002
Mic/Line Input 4
40003
Gain values range from 0 dB to 42 dB and must be in 3 dB steps.
For example:
,
,
,
, and so on.
0
3
6
9
Attenuation values must be in 1 dB steps.
Gain Value Range
to
0
42
to
0
42
to
0
42
to
0
42
Output
OID
Output 1
60000
Output 2
60001
Output 3
60002
Output 4
60003
AXI 22 AT and AXI 44 AT • Remote Control
Attenuation Value
Range
to -
0
100
to -
0
100
to -
0
100
to -
0
100
38