Specifications - Mira Advance Standard J97I Installation And User Manual

Hide thumbs Also See for Advance Standard J97I:
Table of Contents

Advertisement

Specifications

Supply Source
Maximum Static Pressure
Minimum Static Pressure
Maximum Inlet Temperature
Minimum Inlet Temperature
Inlet Connection
Outlet Connection
Nominal Rating at 230 V
Nominal Rating at 240 V
Supply Fuse/Circuit Breaker
Residual Current Device RCD
Supply Cable
Isolation Switch
Maximum Ambient Temperature
Minimum Ambient Temperature
Duty Cycle
Standards and Approvals
The Mira Advance ATLP complies with the requirements of the BEAB Care Mark
Standard and the relevant directives for CE marking.
The BEAB Care mark is invalid if the product is not installed and used in accordance
with the manufacturer's specifications and instructions.
Gravity fed or pumped cold water only.
100 kPa (1 bar)
0.8 kPa (0.008 bar) (10 kPa BEAB Care)
30°C (20°C BEAB Care)
2°C (5°C BEAB Care)
½" BSP male & 15 mm compression
fitting.
½" BSP male fitting
8.3 kW
9.0 kW
40 Amps
30 mA
No larger than 16 mm²
Note: Refer to current IEE regulations
and BS 7671 to determine minimum
cable size.
45 Amp Double pole, with 3 mm contact
separation.
30°C
2°C
Continuously rated
7