Adjustment Procedure - Integra DTR-5.9 Service Manual

Hide thumbs Also See for DTR-5.9:
Table of Contents

Advertisement

ADJUSTMENT PROCEDURE-1

IDLING CURRENT ADJUSTMENT
[When]
1. Exchange Power transistor (Q6050 - Q6056, Q6060 - Q6066).
2. Amplifier PC board (NAAF-9424).
[Procedure]
Refer to "ADJUSTMENT PROCEDURE-2 " for the adjustment points and the test points.
<Note> No load and No signal
1. Before idling adjustment, turn the trimming resistors fully to counter clockwise.
2. Connect the dc voltmeter to test points,
using two 100 ohm resistors between the poles of the jig terminal and the dc voltmeter terminals.
DC voltmeter
3. Connect the ac power cord to a wall outlet. And press On/Standby button to turn the power on.
4. Adjust the trimming resistors as the following procedure immediately after power on.
Channel
Front Left
Front Right
Center
Surround Left
Surround Right
Surround Back Left
Surround Back Right
5. Wait for 4 - 6 minutes. (Heat running)
6. Re-adjust the trimming resistors as the following procedure.
Channel
Front Left, Front Right
and Center
Surround Left
Surround Right
Surround Back Left
Surround Back Right
<Notes>
Idling currents are stabilized in about 10 minutes after power on.
7. Disconnect the dc voltmeter.
8. Press
button to turn the power off. And disconnect the ac power cord.
On/Standby
100 ohms
Jig terminal
(1/4 watt)
Adjustment point
Test point
R6040
R6040
P6080
P6080
R6041
R6041
P6081
P6081
R6042
R6042
P6082
P6082
R6043
R6043
P6083
P6083
R6044
R6044
P6084
P6084
R6045
R6045
P6085
P6085
R6046
R6046
P6086
P6086
Measured value
Adjustment value
In below 9 mV
9 mV
9 mV
In case 9 - 11 mV
Leave it as it is
Leave it as it is
In case over 11 mV
11 mV
11 mV
In case below 6 mV
6 mV
6 mV
In case 6 - 8 mV
Leave it as it is
Leave it as it is
In case over 8 mV
8 mV
8 mV
Test point
ID+
ID-
Adjustment value
2.5 mV
2.5 mV
1.5 mV
1.5 mV
Specifications
12 +/- 3 mV
12 +/- 3
9 +/- 3 mV
9 +/- 3
DTR-5.9

Advertisement

Table of Contents
loading

Table of Contents