If the server is installed in a rack, locate the server by identifying the illuminated rear UID LED button.
5.
Disconnect the power cords.
6.
The system is now without power.

Extend the server from the rack

NOTE:
without powering down the server or disconnecting peripheral cables and power cords.
These steps are only necessary with the standard cable management solution.
Power down the server (on page 25).
1.
Disconnect all peripheral cables and power cords.
2.
Loosen the front panel thumbscrews.
3.
Extend the server on the rack rails until the server rail-release latches engage.
4.
WARNING:
is adequately stabilized before extending a component from the rack.
WARNING:
release latches and sliding the server into the rack. The sliding rails could pinch your fingers.
After performing the installation or maintenance procedure, slide the server into the rack:
5.
Slide the server fully into the rack.
a.
Secure the server by tightening the thumbscrews.
b.
Connect the peripheral cables and power cords.
6.

Remove the server from the rack

To remove the server from an HP, Compaq branded, telco, or third-party rack:
Power down the server (on page 25).
1.
Extend the server from the rack (on page 26).
2.
Disconnect the cabling and remove the server from the rack. For more information, refer to the
3.
documentation that ships with the rack mounting option.
Place the server on a sturdy, level surface.
4.

Safety considerations

Before performing service procedures, review all the safety information.

Preventing electrostatic discharge

To prevent damaging the system, be aware of the precautions you need to follow when setting up the
system or handling parts. A discharge of static electricity from a finger or other conductor may damage
system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the
device.
To prevent electrostatic damage:
If the optional cable management arm option is installed, you can extend the server
To reduce the risk of personal injury or equipment damage, be sure that the rack
To reduce the risk of personal injury, be careful when pressing the server rail-
Removal and replacement procedures 26