Troubleshooting
Error
Meaning
E
7
3 7 Error Z phase
E
7
3 8 Error Z phase
E
9
0 7 Error search X-axis X-axis sensor does not res-
E
9
0 8 Error search Y-axis Y-axis sensor does not res-
E
9
1 0 Error clamp foot
search
E
9
1 1 Error clamp foot
motor
E
9
1 2 Internal error
E
9
1 3 Error thread catcher
search
E
9
1 4 Error thread catcher
motor
Service Instructions 512-211-01/532-211-01 - 01.0 - 10/2017
Possible cause
Z signal no longer changes • Check motor / encoder.
Z signal inaccurate /
encoder has no signal
pond
pond
Clamp foot sensor does not
respond
Clamp foot motor does not
operate corrrectly
-
Thread catcher sensor
does not respond
Thread catcher motor does
not operate corrrectly
Remedial measures
Process in the order specified!
• Check motor / encoder.
• Set main switch to OFF.
• Check sensor.
• Set main switch to OFF.
• Check sensor.
• Set main switch to OFF.
• Check sensor.
• Set main switch to OFF.
• Check motor and connection.
• Notify DA Service
• Set main switch to OFF.
• Check sensor.
• Set main switch to OFF.
• Check motor and connection.