Monitoring Status Through Software - IBM DS3500 Installation, User's, And Maintenance Manual

System storage
Table of Contents

Advertisement

Note: Be sure to install the Storage Manager event monitoring service to enable continuous monitoring of
the status of the storage subsystem. For more information about the importance of this information, see

"Monitoring status through software."

Monitoring status through software
Use the Storage Manager software to monitor the status of the storage subsystem. Run the software
constantly, and check it frequently.
Note:
1. You can monitor only storage subsystems that are within the management domain of the
storage-management software.
2. If you have not installed the Storage Manager Event Monitor service as part of the
storage-management software installation, the Storage Manager Enterprise Management window must
remain open. (If you close the window, you will not receive any alert notifications from the managed
storage subsystems.)
For more information, see the Enterprise Management online help.
Important: See the DS Storage Manager 10 Installation and Host Support Guide for the applicable operating
system for instructions for installing the Storage Manager software. The document is in the
Documentation folder on the IBM System Storage DS3500 Support DVD.
To download the latest version of the Storage Manager software, controller firmware, NVSRAM firmware,
and the latest ESM firmware, go to http://www.ibm.com/servers/storage/support/disk/.
The Storage Manager software provides the best way to diagnose and repair storage-subsystem failures.
The software can help you:
v Determine the nature of the failure
v Locate the failed component
v Determine the recovery procedures to repair the failure
Amber (needs attention) LEDs do not necessarily indicate which component has failed or must be
replaced or which type of recovery procedure you must perform. In some cases (such as when a drive
exceeds its Predictive Failure Analysis [PFA] threshold), the amber LED is not lit. Only the Storage
Manager software can detect the failure.
For example, the recovery procedure for a PFA flag (impending drive failure) on a drive varies depending
on the drive status (hot spare, unassigned, RAID level, current logical drive status, and so on).
Depending on the circumstances, a PFA flag on a drive can indicate a high risk of data loss (if the drive
is in a RAID 0 volume) or a minimal risk (if the drive is unassigned). Only the Storage Manager software
can identify the risk level and provide the necessary recovery procedures.
Note: For PFA flags, the system-error LED and drive status LEDs are not lit, so checking the LEDs will
not notify you of the failure, even if the risk of data loss is high.
Recovering from a storage-subsystem failure might require you to perform procedures other than
replacing the component (such as backing up the logical drive). The Storage Manager software provides
these procedures.
Attention: Not following the software-recovery procedures can result in data loss. In addition, always
replace a failing component as soon as possible to minimize additional failures that might occur, causing
loss of data access.
Chapter 4. Operating the storage subsystem and storage enclosure
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exp3500

Table of Contents