Table 6-2. Troubleshooting information (continued)
Component
Problem indicator
One or more
One or more green
drives
LEDs off
All drives
Front panel
Some or all
Intermittent or
components
sporadic power loss
Drives
Unable to access any
drives
Subsystem
Random errors
Possible cause
Possible solutions
No activity to the
No action is required.
drives
No activity to the
No action is required.
drives
Damaged or loose
Check the SAS cables and connections.
SAS cables
ESM failure
Use the controller management software to check
the drive status. Replace the ESM.
Midplane failure
Contact your IBM technical-support representative.
Power supply
Make sure that the cables are connected and the
power supplies are turned on.
Hardware failure
If any other LEDs are lit, contact your IBM
technical-support representative.
Defective ac or dc
1. Check the ac or dc power source.
power source or
2. Secure all installed power cables and power
partially connected
supplies.
power cord
3. If applicable, check the power components
(power supplies, uninterruptible power supply,
and so on).
4. Replace defective power cables.
Power-supply
Check for a fault LED on the power supply and
failure
replace the failed power supply. See "Checking the
LEDs" on page 4-7.
Midplane failure
Contact your IBM technical-support representative.
SAS cable
1. Make sure that the SAS cables are undamaged
and correctly connected.
2. Replace the cables.
ESM failure
Contact your IBM technical-support representative.
Midplane failure
Contact your IBM technical-support representative.