4. Referring to the interconnection diagram at the back of this manual, connect the
lines to the terminal board of the junction box.
5. Fasten the cable glands to fix the cable.
The cables must project 10 mm inside of the junction box.
Note: Fasten the cable glands by hand. Do not use a wrench, to prevent damage
to the gland.
6. Reattach the cover to the junction box.
7. To prevent water from entering into the unit, apply the silicone sealant (KE-347-
W-100, supplied) to cable entrances (three locations).