2. WIRING
2.1.4
Alarm Monitoring System
Connect the AMS (Alarm Monitoring System) to J310 of the DCU. The connector J310
can output/input signals shown below.
Output
• System failure
• Power failure
• Local ACK
Pin #
1
RD_H_AMS
2
RD_C_AMS
3
TD_A_AMS
4
TD_B_AMS
5
GND
6
SYS_FAIL+
7
SYS_FAIL-
8
POWER_FAIL+
9
POWER_FAIL-
10
LOCAL_ACK+
11
LOCAL_ACK-
12
REMOTE_ACK+
13
REMOTE_ACK-
14
BUZZER_STOP+
15
BUZZER_STOP-
16
NC
System failure (output)
The VR-7000 notifies the AMS that an alert has been generated. The system failure
signal is output as normally closed (NC).
Contact Rating
Voltage: Less than 32 V
Current: Less than 30 mA
System failure
ON
OFF
Normal condition
Alert occurred
2-6
Connector J310
Signal name
Input/Output
Buzzer
Alert activated
ACK
Buzzer stop
Alert continued
Input
• Remote ACK
• Buzzer stop
Input
TTYCSLA-4
Output
-
No connection
Output
Output
Output
MPYC-12
Input
Input
-
No connection
J310
6
SYS_FAIL+
7
SYS_FAIL-
500 ms
Alert stop
Buzzer
Alert activated
Another alert occurred
(2nd alert)
Cable