1. MOUNTING
3. Remove the cable gland from the cable entrance.
4. Fabricate the cable, then pass the cable through the cable gland and cable en-
trance.
See appendix 2 for how to fabricate the cable.
5. To prevent the cable from being disconnected, attach the cable tie (supplied) to
the cable (see the figure below).
Cable jacket
Cable jacket
6. Connect the cable to the unit. For details, see section 2.6 and interconnection di-
agram at the back of this manual.
7. After wiring, fasten the nut so the clearance between it and cable gland is 3 mm
or less (see figure below).
8. Fasten the front panel to the waterproof cover with the four binding screws re-
moved at step 1.
Note 1: Before fixing the front panel, make sure the waterproof gasket is correctly
seated in the groove in the waterproof cover.
Note 2: Take care to not to bend or pinch the cable.
1-16
Cable tie:
Wrap around the vinyl tape.
Armor
Vinyl tape (Width: 20 mm)
3 mm or less