3. INITIAL SETTINGS
3.2

How to Set External Equipment

The FELCOM 18 is set at the factory to accept the distress alert/received call unit IC-
305, up to three alarm units IC-306 and the SSAS alert unit IC-307. If the configuration
is different, change the setting to OFF as below.
1. Press the F8 key to show the [Setup] menu.
2. Press the 1 key to show the [System Setup] menu.
3. Press the ↓ key to select [Command Window], and then press Enter key to show
the [Command Window] screen.
4. Enter the [Enter JOB No.:], and then press the Enter key.
5. Enter the [PASSWORD:], and then press the Enter key.
[Main Menu] is highlighted.
6. Press the 1 and Enter keys in order.
7. Press the number key for unit not connected.
[
SSAS
1. OFF
2. IC-307 (Standard SSAS)
3. IC-307 (Russia SSAS)
4. SSAS(Momentary SW)
E: Exit
8. If the unit is not connected, press the 1 key, and the Enter key.
To return to the [Remote Box Setup] menu, press the E key (not any numeric key).
9. Repeat step 7 to step 8 for other units not connected.
10. Press the Esc key several times to close the menu.
3-2
Setup
System Setup
System Date & Time
01:53 02-02-25 (YY-MM-DD)
IMN
Command Window
MES Operation Mode
INMARSAT-C
[
Main Menu
]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
Enter JOB No.: 1
[
]
Remote Box Setup
1. SSAS
OFF
2. IC-305
ON
3. IC-306 No.1
ON
4. IC-306 No.2
OFF
5. IC-306 No.3
OFF
E: Exit
Enter No.:
Command Window screen
]
Setting window for IC-307