Omron SYSDRIVE 3G3EV User Manual page 87

Compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV:
Table of Contents

Advertisement

Appendix A
List of Constants Used with 3G3EV
Constant
Indi-
no.
cators
n01
n02
n03
n04
n06
n09
n11
n12
n20
7-10
Description
Constant
0: Only n01 can be set.
write-inhibit
1: All constants can be set.
selection
8: Constant settings are initialized.
/constant
9: Inverter is initialized in 3-wire
initialization
Mode operation
selection
0
1
2
3
4
5
Stop mode
0: Deceleration stop
selection
1: Free running
f%r: forward rotation
Forward
/Reverse
reU: reverse rotation
rotation
selection
Multi-function
0: Forward/reverse rotation command
input selection
1: Fault reset
2: External fault (external fault when ON)
3: External fault (external fault when
4: Multi-step speed command
Multi-function
0: Fault occurrence
output selection
1: Operation in progress
2: Frequency matching
Frequency
0.0 to 400 (Hz)
reference 1
Frequency
0.0 to 400 (Hz)
reference 2
Acceleration
0.0 to 999 (seconds)
time
Setting range
sequence mode.
Run command
Digital Operator
Control terminal
Digital Operator
Control terminal
Digital Operator
Control terminal
OFF)
Chapter 7
Standard Model
Setting
Frequency
reference
Digital Operator
Digital Operator
Control terminal
(voltage input)
Control terminal
(voltage input)
Control terminal
(amperage
input)
Control terminal
(amperage
input)
[6.0]
[0.0]
[10.0]