Omron SYSDRIVE 3G3EV User Manual page 60

Compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV:
Table of Contents

Advertisement

Operation
H Data Display and Action to be Taken when Warning Status
Arises
The ALARM indicator flashes when warning status arises. The data display section also
flashes.
When warning status arises, no error code is output.
Eliminating the cause recovers the system automatically.
Data
display
ef
Simultaneous input of forward and
flashing
reverse rotation commands
Forward and reverse rotation
commands were simultaneously input
for 0.5 second or more. The Inverter
decelerates and stops the motor.
uU
Main circuit undervoltage (UV)
flashing
The DC voltage of the main circuit
dropped below the low-voltage
detection level when the Inverter was
stopped.
%U
Main circuit overvoltage (OV)
flashing
The DC voltage of the main circuit
exceeded the overvoltage detection
level when the Inverter was stopped.
%h
Radiation fin overheated (OH)
flashing
The radiation fin overheated when the
Inverter was stopped.
Digital Operator stopped (STP)
flashing
The STOP/RESET Key on the Digital
Operator was pressed while the
Inverter was being operated using
control circuit terminals SF and SR.
The Inverter decelerates and stops
the motor.
Description
Action
• Review the sequence.
• Check the power voltage.
• Check the power input line for discon-
nection.
• Check the terminal block screws for
looseness.
• Check the power voltage.
• Check the ambient temperature.
• Install a cooling fan or air conditioner.
• Open both SF and SR.