8-1-2. Install the terminal block
(1) Attach the terminal block to the indoor unit firmly with 1 screw.
(2) Place the wiring as per the figure.
Place the wires from the terminal
(Front view)
block under the other wires.
Screw
Terminal block (with wire)
(3) Connect the wires from the terminal block to the indoor unit main PCB by inserting to connector (CN12).
(4) Change the DIP switch setting as shown in the following photograph.
(Indoor unit main PCB)
Terminal block
wires
• Be careful not to damage the parts on the board. Otherwise, it will cause malfunction.