6. Attach the Yoke to the Gooseneck by rotating the device clockwise for a minimum
of four turns. Ensure that the device is level.
7. The two set screws can now be inserted to increase stability. Tighten the set screws
to between 214.2 and 250.0 inch pounds (lbf-in).
8. If the AP 7181 you are mounting is a Mesh Point Root node or a Mesh Point node
with an external device (e.g. surveillance camera) perform the required Ethernet
cabling.
The Ethernet cable gland is optimized for cables of diameter .39 to .55 inches. Smaller
diameter cables can achieve a watertight seal if the cable gland is properly tightened during
Hardware Installation