Comtech EF Data CDM-760 Installation And Operation Manual page 181

Advanced high-speed trunking modem
Table of Contents

Advertisement

Ethernet Interface Operation
CDM-760 Advanced High-Speed Trunking Modem
System Account Access Information
At the time of publication, the "SMTP Server", "SMTP Domain Name", and "SMTP
Destination" text fields are non-functional.
Enter a Read-only, Read/Write, or Admin Name and Password. A name or password can be
any alphanumeric combination with a maximum length of 10 characters. The factory default
names/passwords are as follows:
Host Access List
The Host Access List allows you to define a list of remote client PCs which can connect to the
CDM-760 via HTTP and SNMP.
Enter an IP (#) / Mask (IP address and a subnet mask) for each Access List entry.
For example, if you want to grant access to a remote client PC with an IP Address of
10.10.10.1, and any PC on a subnet of 192.168.10.xxx, then you would define the Access List
as:
Make sure 'IP 3 / Mask' and 'IP 4 / Mask' are not 0.0.0.0/0. An entry with
0.0.0.0/0 allows access to any PC.
Use the Access List drop-down list to select Enable or Disable. When disabled, any client PC
may connect via HTTP and SNMP.
Click [Submit Admin] to save.
o Read-only
monitor/1234
o Read/Write
opcenter/1234
o Admin
comtech/comtech
IP 1 / Mask:
10.10.10.1/32
IP 2 / Mask:
192.168.10.0/24
7–14
Revision 4
MN-CDM760

Advertisement

Table of Contents
loading

Table of Contents