Step
1
Check evaporator temp. sensor resistance
1) Disconnect ECM connectors with ignition switch at OFF
position.
2) Check resistance between terminals "C41-10" and "G04-
14" and terminals "G04-11" and "C41-10".
Evaporator temp. sensor resistance
At 0 °C: 6.3 – 6.9 kΩ
At 25 °C: 1.8 – 2.2 kΩ
Is it within specification?
2
Check A/C switch signal
1) Check voltage at terminal "G04-16" under each condition
given as follows.
Voltage at terminal "G04-16"
Ignition switch ON, A/C switch OFF: 10 – 14 V
Ignition switch ON, A/C switch ON and blower motor
switch 1st speed position or more: 0 – 1 V
Is check result satisfactory?
3
Check A/C condenser fan control system
Is A/C cooling fan started when A/C switch and heater
blower switch turned ON?
Action
I2RH01110136-01
Engine General Information and Diagnosis:
Yes
Go to Step 2.
Go to Step 3.
Go to Step 7.
1A-94
No
Faulty A/C evaporator
temp. sensor or its
circuit.
"GRN/BLK" wire open or
short. Poor "G04-16"
terminal connection.
If wire and connection
are OK, faulty A/C
pressure switch, A/C
control module.
Go to Step 4.