Troubleshooting
Control unit diagnostics
Position
Code
10
1
2
Example:
Information index "0C : 0C 00 00 00"
Posi-
Display
tion
1
"0"
2
"C"
":"
3
"0"
4
"C"
5
"0"
6
"0"
7
"0"
8
"0"
9
"0"
10
"0"
Temperature and pressure values
Most recent temperature and pressure values captured in primary and secondary
circuits.
156
(cont.)
Explanation
Maximum operating pressure (MOP) was reached; control type
(superheating/evaporation pressure control) in refrigerant cir-
cuit was adjusted.
Fault due to impermissible combination of refrigerant circuit
conditions. A serious EEV controller fault has occurred, as the
heat pump control unit only transfers permissible parameter
combinations to the EEV controller.
Codes
Explanation (Tab. E)
(Tab. C)
0
4
High pressure sensor faulty, determined from a
plausibility check of values
8
Hot gas temperature sensor faulty, determined
from a plausibility check of values
0
4
High pressure sensor faulty, reported directly from
EEV controller
8
Hot gas temperature sensor faulty, reported
directly from EEV controller
0
0
0
0
0
0