Assembly Notes
Insert the power supply into the chassis with the forward side up to allow the AC line connector to
pass through the hole in the chassis.
Torque the six M3x8 Torx screws to 6 in-lbs (.68 Nm).
Connect the ground terminal to the chassis. Torque the M3x8 Torx screw to 6 in-lbs (.68 Nm).
Connect the safety switch cable to J3 on the power supply. Then connect the power supply/controller
ECA cable to P1, the ballast/power supply cable to J1 and the lamp control cable to J4 on the power
supply.
Make sure that you route the safety switch cable through the eye at the front left side of the chassis.