3.
To remove the lamp, loosen the captive screw that secures it in the projector, swing the bail on
the top of the lamp module up from its storage position, and then pull the module out of the
projector.
Assembly Notes
The lamp must be seated properly to fully ignite. Make sure the two alignment pins on the lamp
module engage the holes inside the lamp cavity.
Make sure the bail on the lamp module is folded down in storage position. It snaps into position.
NOTE
If the lamp door does not fit flush in the door opening, it is probably because the bail is not
completely folded down.
You must replace the lamp door for the projector to operate.
If you installed a new lamp module, follow the directions below to reset the lamp timer.
Press the Menu button and navigate to the Main Menu>Settings>Service menu. Select Lamp Reset
to reset the lamp timer.
After you reset the lamp timer, read the timer value to make sure it was reset. Navigate to the About
screen from the Main Menu, then view the Lamp Hour value. It should show 0 hours.