Start-Up And Configuration; Pre-Operation Checks - Daikin EKHVWQ002AAV3 Installation Manual

Domestic hot water heat pump
Hide thumbs Also See for EKHVWQ002AAV3:
Table of Contents

Advertisement

Possible types of benefit kWh rate power supply
Possible connections and requirements to connect the equipment to
such power supply are illustrated in the figure below:
[D-01]=1
1
L N
1
S2S
2
3
2
L N
1
2
S2S
3
3
L N
1
2
S2S
3
3
5 6
1
Benefit kWh rate power supply box
2
Receiver controlling the signal of the electricity company
3
Power supply to unit
4
Voltage free contact to indoor unit
When the unit is connected to a benefit kWh rate power supply, the
voltage free contact of the receiver controlling the benefit kWh rate
signal of the electricity company must be connected to clamps 5 and
6 of X3M (as illustrated in the figure above).
When parameter [D-01]=1 at the moment that the benefit kWh rate
signal is sent by the electricity company, that contact will open and
the unit will go in forced off mode
When parameter [D-01]=2 at the moment that the benefit kWh rate
signal is sent by the electricity company, that contact will close and
the unit will go in forced off mode
Type 1
This type of benefit kWh rate power supply is not interrupted.
Type 2
This type of benefit kWh rate power supply is interrupted after elapse
of time.
Type 3
This type of benefit kWh rate power supply is interrupted immediately.
(1) When the signal is released again, the voltage free contact will close and
the unit will restart operation. It is therefore important to leave the auto
restart function enabled. Refer to
(2) When the signal is released again, the voltage free contact will open and
the unit will restart operation. It is therefore important to leave the auto
restart function enabled. Refer to
Installation manual
16
[D-01]=2
1
L N
1
S2S
2
4
3
2
L N
1
2
S2S
4
3
3
L N
1
2
S2S
4
3
4
X3M
A1P
X40A
(1)
.
(2)
.
"[3] Miscellaneous" on page
19.
"[3] Miscellaneous" on page
19.
INFORMATION
When connecting the equipment to a benefit kWh rate
power supply, change field setting [D-01].
INFORMATION
If the benefit kWh rate power supply is of the type that
power supply is not interrupted, the unit will be forced to
off.
When the benefit kWh rate signal is sent, the centralised
control indicator e will appear to indicate that the benefit
kWh rate is active.
4
10. S
-
TART
UP AND CONFIGURATION
The unit should be configured by the installer to match the installation
environment (outdoor climate, installed options, etc.) and user
expertise.
4
CAUTION
It is important that all information in this chapter is read
sequentially by the installer and that the system is
configured as applicable.
INFORMATION
4
When a power failure occurred and the power returns to
the unit, the system will automatically restore it's settings
and restart.

10.1. Pre-operation checks

DANGER
Switch off the power supply before making any
connections.
After the installation of the unit, check the following:
1
Field wiring
Make sure that the field wiring has been carried out according to
the instructions described in the chapter
on page
12, according to the wiring diagrams and according to
European and national regulations.
2
Fuses and protection devices
Check that the fuses and other locally installed protection
devices are of the size and type specified in the chapter
"Technical specifications EKHVWQ002AAV3" on page
sure that neither a fuse nor a protection device has been
bypassed.
3
Earth wiring
Make sure that the earth wires have been connected properly
and that the earth terminals are tightened.
4
Internal wiring
Visually check the switch box and the inside of the unit on loose
connections or damaged electrical components.
5
Installation
Check that the unit is properly installed, to avoid abnormal
noises and vibrations when starting up the unit.
6
Damaged equipment
Check the inside of the unit on damaged components or
squeezed pipes.
"Electrical wiring work"
27. Make
EKHVWQ002AAV3 + EKHHS200+260AA1V3
Domestic hot water heat pump
4PW65342-1A – 10.2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhhs200aa1v3Ekhhs260aa1v3