Error
code
Failure cause
Ambient temperature thermistor
H9
failure (ambient thermistor is
broken)
Domestic hot water tank
HC
thermistor failure
Discharge pipe thermistor failure
J3
Aircoil thermistor frost detection
J6
failure
Electric component failure
L3
Electric component failure
L4
Electric component failure
L5
Electric component failure
P4
Refrigerant failure (due to
U0
refrigerant leak)
Main circuit voltage failure
U2
Communication failure
U4
Communication failure
U5
Communication failure
UA
14. I
MPORTANT INFORMATION REGARDING THE
REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type:
R410A
(1)
GWP
value:
1975
(1)
GWP = global warming potential
INFORMATION
National implementation of EU regulation on certain
fluorinated greenhouse gases may require to provide the
appropriate official national language on the unit.
Therefore,
an
additional
greenhouse gases label is supplied with the unit.
Sticking instructions are illustrated on the backside of that
label.
15. D
ISPOSAL REQUIREMENTS
Dismantling of the unit and treatment of parts must be done in
accordance with relevant local and national legislation.
EKHVWQ002AAV3 + EKHHS200+260AA1V3
Domestic hot water heat pump
4PW65342-1A – 10.2010
Corrective action
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
Contact your local dealer.
multilingual
fluorinated
16. U
NIT SPECIFICATIONS
16.1. Technical specifications EKHVWQ002AAV3
Nominal capacity
Casing material
Dimensions H x W x D
Weight
• with packaging
• without packaging
Connections
• water inlet/outlet
• water drain
Pump
• type
• no. of speed
(a)
Sound pressure level
Internal water volume
Operation range - water side
Operation range - ambient air
• domestic hot water
(a) At 1 m in front of the unit (free field condition)
(b) Temperatures above 60°C are achieved by booster heater.
(c) field setting
16.2. Electrical specifications EKHVWQ002AAV3
Phase
Frequency
Voltage range
• minimum
• maximum
Voltage tolerance
Maximum running current
Recommended field fuse
16.3. Specifications EKHHS200+260AA1V3
Storage capacity
Material
Overall dimensions H x W x D
Connections
Inspection opening
Weight (empty)
Mounting
Maximum pressure domestic
hot water tank
Maximum primary working
pressure (heating side)
Maximum tempreature
domestic hot water
Booster heater
• Power supply
• Running current
• Capacity
(a) MBSP = Male British Standard Pipe
(b) For floor standing next to the heat pump module, the EKFMHHSAA kit is needed.
(kW)
2.5
Pre-coated sheet metal
(mm)
730 x 600 x 595
(kg)
153
(kg)
144
Quick coupling
drain valve
AC motor
position III
(dBA)
47 dBA
(l)
1
(°C)
(b)
35~75
(c)
(°C)
+2~+35
1N~
(Hz)
50
(V)
220
(V)
240
–10%/+6%
(A)
17.4
(A)
20
EKHHS200
EKHHS260
(l)
200
260
Stainless steel
1235 x 600 x 695 1510 x 600 x 695
(mm)
(a)
G 1/2" MBSP
(mm)
Wrench 41
57
66
(kg)
On top of EKHVWQ002AAV3
(bar)
10
(bar)
10
(°C)
75
230 V 50 Hz 1~
(A)
7
(kW)
1.5
Installation manual
(b)
27