Start-Up And Configuration; Dip Switch Settings Overview; Room Thermostat Installation Configuration - Daikin EKCBX008BBV3 Installation Manual

Hide thumbs Also See for EKCBX008BBV3:
Table of Contents

Advertisement

12. S
-
TART
UP AND CONFIGURATION
The outdoor unit and indoor unit should be configured by the installer
to match the installation environment (outdoor climate, installed
options, etc.) and user expertise.
CAUTION
It is important that all information in this chapter is read
sequentially by the installer and that the system is
configured as applicable.
DANGER: ELECTRICAL SHOCK
See
"2. General safety precautions" on page

12.1. DIP switch settings overview

DIP switch SS2 is located on the control box PCB (refer to the
chapter
"Indoor unit switch box" in the EBHQ outdoor installation
manual) and allows configuration of domestic hot water tank
installation, room thermostat connection and pump operation.
WARNING
Switch off the power supply before opening the control box
service panel and making any changes to the DIP switch
settings.
DIP
switch
SS2
Description
1
Not applicable for installer
2
Domestic hot water tank
installation
(see
"12.4. Domestic hot
water tank installation
configuration" on page
3
Room thermostat
connection
(see
"12.2. Room
thermostat installation
configuration" on page
4
(a)
This setting
decides the
operation mode of the
heat pump when there is a
simultaneous demand for
more space
heating/cooling and
domestic water heating.
(a) Only applicable in case DIP switch 2 = ON.
(b) Heating/cooling or domestic water heating mode can be restricted by schedule
timer and/or field settings (4, 5, 8).
EKCBX/H008BBV3
Unit for air to water heat pump system
4PW66983-1C – 08.2011
2.
1
2
3
4
ON
OFF
(Default)
Installed
Not installed
(Default)
22)
Room thermostat
No room
connected
thermostat
connected
(Default)
21)
Heating/cooling
Priority to highest
priority
demand side
12.2. Room thermostat installation configuration
When no room thermostat is connected to
the indoor unit, toggle switch SS2-3 should be
set to OFF.
When the room thermostat is connected to
the indoor unit, toggle switch SS2-3 should be
set to ON.
On the room thermostat, confirm the correct settings (6®02=yes,
6®05=9, 6®06=5) to prevent the pump from repeatedly turning on
and off (i.e. chattering), and thereby impacting the lifetime of
the pump.
INFORMATION
When the room thermostat is connected to the indoor
unit, the heating and cooling schedule timers are
never available. Other schedule timers are not
affected. For more information on the schedule timers,
refer to the operation manual.
When the room thermostat is connected to the indoor
unit, and the = button or y button is pressed, the
centralised control indicator e will flash to indicate
that the room thermostat has priority and controls
on/off operation and change over operation.
The following table summarizes the required configuration and
thermostat wiring at the terminal block (X2M: 1, 2, 3, 4) in the control
box. Pump operation is listed in the third column. The three last
columns indicate whether the following functionality is available on
the user interface (UI) or handled by the thermostat (T):
space heating or cooling on/off (y)
heating/cooling changeover (=)
heating and cooling schedule timers (pr)
Thermostat
No thermostat
(b)
Heating only
thermostat
Thermostat with
heating/cooling
switch
(a) The pump will stop when space heating/cooling is turned off or when the water
reaches the desired water temperature as set on the user interface. With space
heating/cooling turned on, the pump will then run every 5 minutes during 3
minutes to check the water temperature.
Pump
Configuration
operation
• SS2-3 = OFF
determined by
leaving water
• wiring: (non)
(a)
temperature
X2M
1 2 3 4
• SS2-3 = ON
on when space
heating or
• wiring:
cooling is on
(y)
X2M
1 2 3 4
• SS2-3 = ON
on when
• wiring: (see
heating
request by
installation
room
manual of the
thermostat
room
thermostat kit)
• SS2-3 = ON
on when
heating
• wiring: (see
request or
installation
cooling request
manual of the
by room
room
thermostat
thermostat kit)
1
2
3
4
1
2
3
4
y
y
y
y
=
=
=
=
p p p p r r r r
UI
UI
UI
UI
UI
UI
T
T
T
Installation manual
21

Hide quick links:

Advertisement

Table of Contents
loading