Field settings table

First
Second
code
code
Setting name
0
Different operation modes
00
Powerfull operation mode temperature set point
01
Disinfection operation mode tempeature set point
02
Temperature setpoint: reheat minimum
temperature
03
Temperature setpoint: reheat maximum
temperature
04
Status: defines whether the reheat operation is
turned ON(1) or OFF(0)
1
Automatic domestic hot water tank temperature set point calculation
00
Renewal time for set point calculation
01
Mnimum automatic temperature set point
02
Maximum automatic temperature set point
2
Disinfection operation
00
Operation interval
01
Status
02
Start time
03
Status
04
Interval
3
Miscellaneous
00
Auto restart
01
User permission level
02
Status
03
Status
4
Miscellaneous
03
Simultanuous operation of booster heater and
heatpump
04
Not applicable. Do not change the default value.
6
Miscellaneous
00
Start
01
Stop
02
Booster heater economical timer
03
Powerful mode priority
04
Quiet mode level
7
Miscellaneous
01
Domestic hot water step length
02
Not applicable. Do not change the default value.
03
Not applicable. Do not change the default value.
04
T-ambient
8
Automatic setpoint calculation
00
Set point (weekdays)
01
Set point (week-end)
02
Initial city water temperature
03
Reset demand
04
Domestic hot water tank volume
D
Benefit kWh rate power supply/Local shift value weather dependent
01
Benefit kWh rate power supply
E
Unit information readout
00
Readout of the software version
01
Readout of the EEPROM version
02
Readout of the unit model identification
Installation manual
22
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
40
35~50
60
55~75
40
35~75
45
35~75
0 (OFF)
0/1
6:00
0:00~23:30
42
35~75
60
35~75
Mon~Sun
Fri
All
1 (ON)
0/1
23:00
0:00~23:00
0 (OFF)
0/1
32
5~60
1 (ON)
0/1
3
2/3
0 (OFF)
0/1
0 (OFF)
0/1
0
0/1/2/3
1
10
2~20
0
0~10
0
0~95
1 (ON)
0/1
1
1/2/3
2
2~40
3
0
2
–25~+10
45
35~75
50
35~75
15
0~30
0 (OFF)
0/1
0 (260 l)
0/1)
0
0/1/2
Read only
Read only
Read only
EKHVWQ002AAV3 + EKHHS200+260AA1V3
Domestic hot water heat pump
Step
Unit
1
°C
1
°C
1
°C
1
°C
1
0:30
hour
1
°C
1
°C
1
1:00
hour
1
1
minute
1
1
1
1
1
1
°C
1
°C
5
minute
1
1
1
°C
1
°C
1
°C
1
°C
1
°C
1
1
1
4PW65342-1A – 10.2010