Daikin EKHBH016AA Operation Manual
Daikin EKHBH016AA Operation Manual

Daikin EKHBH016AA Operation Manual

Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system

Advertisement

OPERATION MANUAL

Indoor unit for air to water heat pump and
sanitary warm water tank for air to water
heat pump system
EKHBH016AA
EKHBX016AA

Advertisement

Table of Contents
loading

Summary of Contents for Daikin EKHBH016AA

  • Page 1: Operation Manual

    OPERATION MANUAL Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH016AA EKHBX016AA...
  • Page 2: Table Of Contents

    Programming and consulting the schedule timer ........7 reversible air to water Daikin ERHQ heat pumps. These units are Getting started ..................7 designed for wall mounted indoor installation and used for both Programming ..................
  • Page 3: Operating The Unit

    Ask your capacity to heat up your house. installer or your local Daikin dealer for more It is advised to install a room thermostat connected to the indoor information on permission levels.
  • Page 4: Name And Function Of Buttons And Icons

    This icon indicates that the OFF action is selected when programming the schedule timer. INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation. Consult your Daikin Dealer. SET TEMPERATURE DISPLAY 9 The display shows the current set temperature of the installation.
  • Page 5: Setting Up The Controller

    SANITARY WATER HEATING BUTTON v Setting up the controller This button enables or disables heating of the sanitary water. This button is not used when the sanitary water tank is not installed. After initial installation, the user can set the clock and day of the week.
  • Page 6: Description Of The Operation Modes

    Description of the operation modes Controller operations Manual operation Space heating operation ( In manual operation, the user manually controls the settings of the In this mode, heating will be activated as required by the water installation. The last setting remains active until the user changes it or temperature set point.
  • Page 7: Schedule Timer Operation

    Selecting powerful sanitary heating operation The programmed schedule is time driven. Therefore, it Press v for 5 seconds to activate powerful sanitary heating is essential to set the clock and the day of the week operation. correctly. Refer to "Setting the Clock" on page Icons start flashing.
  • Page 8: Programming And Consulting The Schedule Timer

    What can the schedule timer NOT do? Due to the fact that the schedule timer cannot switch The schedule timer can not change the operation mode from space between operation modes (cooling or heating) and the fact cooling to space heating or vice versa. that each programmed action implies a cooling setpoint and a heating setpoint, the following situations may occur: How to interpret the programmed actions...
  • Page 9: Programming

    Programming Programming space cooling or space heating is carried out as follows: Programming space cooling or space heating Returning to previous steps in the programming NOTE procedure without saving modified settings is done by pressing the pr button. Use the = button to select the operation mode (cooling or heating) you want to program.
  • Page 10: Consulting Programmed Actions

    10 Press the < button for 5 seconds to store the programmed Programming quiet mode, booster heating or sanitary heating actions. If the < button is pressed when action number 3 is displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted. You automatically return to step 4.
  • Page 11: Tips And Tricks

    Tips and tricks IELD SETTINGS Programming the next day(s) The indoor unit should be configured by the installer to match the After confirming the programmed actions of a specific day (i.e. after installation environment (outdoor climate, installed options, etc.) and pressing the <...
  • Page 12: Detailed Description

    [1-03] Set point at high ambient temperature (Hi_Ti): the NOTE Before shipping, the set values have been set as target outgoing water temperature when the outdoor shown under "Field settings table" on page temperature equals or rises above the high ambient temperature (Hi_A).
  • Page 13 [3] Auto restart [5-03] Space heating priority temperature: outdoor temperature below which the sanitary water will be heated by When power returns after a power supply failure, the auto restart the booster heater only, i.e. low outdoor temperature. function reapplies the user interface settings at the time of the power [5-04] Set point correction for sanitary water temperature: set supply failure.
  • Page 14 [7] Sanitary water step length [8] Sanitary water heating mode timer Applies only to installations with a sanitary water tank. Applies only to installations with a sanitary water tank. When the sanitary water is heated and the sanitary water set point The 'sanitary water heating mode timer' field settings defines the temperate (as set by the user) has been reached, the booster heater minimum and maximum sanitary water heating times, and minimum...
  • Page 15 [8-03] Booster heater delay time: specifies the start-up time [A] Quiet mode delay of the booster heater operation after start of the heat This field setting allows to select the desired quiet mode. Two quiet pump sanitary operation. modes are available: quiet mode A and quiet mode B. In quiet mode A, priority is given to the outdoor unit operating quietly under all circumstances.
  • Page 16: Field Settings Table

    Field settings table Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit User permission level User permission level — Weather dependent set point Low ambient temperature (Lo_A) –10 –20~5 °C...
  • Page 17: Maintenance

    field wiring have to be carried out at regular intervals, preferably yearly. This maintenance should be carried out by your local Daikin technician. Besides keeping the remote controller clean by means of a soft damp cloth, no maintenance is required by the operator.
  • Page 18 NOTES NOTES...
  • Page 20 4PW36977-1B Zandvoordestraat 300, B-8400 Oostende, Belgium...