FOR YOUR SAFETY

This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and information
in CAN/CGA B149 (in Canada) or the National Fuel
Gas Code ANSI Z223.1 (in the USA), regarding
requirements for combustion and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit must
be disconnected.
Gas Input Capacity:
Natural Gas
38,000
Propane
38,000
Min. Input
(with Proflame GTMF remote)
Natural Gas
25,000
Propane
30,000
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to 4,500'
(0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 140 CFM.
Log Set: Ceramic fibre, 6 per set - LRI6E
Glass Crystals: 11 lbs of glass crystals - HRI6E
Vent System: 3" x 4" The efficiency rating of the
appliance is a product thermal efficiency rating
determined under continuous operating conditions
and was determined independent of any installed
system.
10 |
LRI6E / HRI6E Direct Vent Gas Insert
GAS PRESSURE
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa).
INSTALLATION INTO A SOLID FUEL
BURNING FIREPLACE OR FACTORY
BUILT FIREPLACE
The LRI6E / HRI6E Gas Inserts have been tested
and approved to be vented into any masonry fire-
place or approved solid fuel burning factory built
Btu/h
fireplace that will allow the insert to physically fit into
the firebox. Refer to "Minimum Fireplace Dimen-
Btu/h
sions" section for minimum fireplace clearances.
If the factory built fireplace* height is too low for
your Insert, you may remove the smoke baffle
Btu/h
plate, damper, refractory (firebricks), glass doors,
Btu/h
screen rails, screen mesh and log grates from the
factory built fireplace as long as these items are
saved and are reinstalled in the event that the Insert
is removed. The fireplace flue damper can be fully
blocked open or removed for installation of the gas
fireplace insert.
Smoke shelves, shields and baffles may be removed
if attached by mechanical fasteners. If any part is
removed it must not weaken the structural integrity
of the factory built fireplace.
The fireplace and fireplace chimney must be clean
and in good working order and constructed of non-
combustible materials.
The surround panels should not seal ventilation
openings on the fireplace.
Chimney clean outs should fit properly.
NOTE: Any alterations made to the listed solid fuel
burning factory built fireplace may void the listing
of the fireplace.
Cutting any sheet metal part of the fireplace, in
which the gas fireplace insert is to be installed is
prohibited.
*Check with your local inspector before commencing
with this installation.
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace into
which the gas fireplace insert is installed.
"WARNING: This fireplace has been converted
for use with a gas fireplace insert only and cannot
be used for burning wood or solid fuels unless all
original parts have been replaced, and the fireplace
re-approved by the authority having jurisdiction."

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI Stand-
ards to make you aware of the following:
FACTORY-BUILT (METAL) WOOD-
BURNING FIREPLACE
REQUIREMENTS
NOTE: Any parts that are removed must be removed
in a way that would allow them to be re-installed if
the insert is ever removed (removal of rivets or
screws is acceptable).
To reference parts—see illustration below.
Must be removed:
1 -Damper
2- Grate (with log set)
May be removed (if applicable):
3- Smoke shelf
4- Internal baffles
5 - Screen
6 & 7 - Masonry lining or refractory
8 - Metal or glass doors
The fireplace must be permanently marked to
indicate that it has been altered and is no longer
suitable for burning solid fuel (wood), unless the
removed parts are re-installed. Cutting of any sheet
metal parts is prohibited.
May be removed (in certain cases):
9 -Metal floor of the firebox
10 - The insulation and any structured rigid frame
members must not be removed or altered (side and
top of door frame, side and top of the face of the
fireplace, metal sides, etc.).
CAUTION:
Firebox floor removal is not covered under the
appliance safety standard (ANSI Z21.88, CSA
2.33) used in the safety certification of this ap-
pliance. The Intertek safety certification does
not apply to this method of installation. Before
installing the appliance using this method, contact
the Authority Having Jurisdiction to determine
if this installation is acceptable in your area.
The sheet metal base of the fireplace must be
left in place and a minimum 1/2" cement board
sheet placed under the entire length and width
of the appliance.
If the factory-built fireplace has no gas access
hole(s) provided, an access hole of 1.5 inch (37.5
mm) or less may be drilled through the lower sides
or bottom of the firebox in a proper workmanship
like manner. This access hole must be plugged
with non-combustible insulation after the gas
supply line has been installed.